目的 评价调强放疗同步补量(IMRT SIB)代替常规照射(全盆外照射加腔内放疗)治疗局部进展期宫颈癌(LACC)的可行性.方法 根据子宫的不同位置选择5例LACC患者,分别制订常规放疗和IMRT SIB计划,比较2种放疗方式靶区的剂量分布.结果 子宫前位、水平位、后位以及偏位时IMRT SIB可以为靶区提供优于常规照射均匀、足量的剂量分布,降低危险器官(直肠、膀胱和小肠)受照体积和剂量;IMRT SIB能够得到较常规放疗更高的A、B点和宫底剂量.但如果小肠邻近或环绕子宫时靶区则欠量.结论 剂量学研究证明LACC IMRT SIB在不同子宫位置(过度前倾前曲位除外)时肿瘤靶区的剂量分布优于常规放疗.
目的 評價調彊放療同步補量(IMRT SIB)代替常規照射(全盆外照射加腔內放療)治療跼部進展期宮頸癌(LACC)的可行性.方法 根據子宮的不同位置選擇5例LACC患者,分彆製訂常規放療和IMRT SIB計劃,比較2種放療方式靶區的劑量分佈.結果 子宮前位、水平位、後位以及偏位時IMRT SIB可以為靶區提供優于常規照射均勻、足量的劑量分佈,降低危險器官(直腸、膀胱和小腸)受照體積和劑量;IMRT SIB能夠得到較常規放療更高的A、B點和宮底劑量.但如果小腸鄰近或環繞子宮時靶區則欠量.結論 劑量學研究證明LACC IMRT SIB在不同子宮位置(過度前傾前麯位除外)時腫瘤靶區的劑量分佈優于常規放療.
목적 평개조강방료동보보량(IMRT SIB)대체상규조사(전분외조사가강내방료)치료국부진전기궁경암(LACC)적가행성.방법 근거자궁적불동위치선택5례LACC환자,분별제정상규방료화IMRT SIB계화,비교2충방료방식파구적제량분포.결과 자궁전위、수평위、후위이급편위시IMRT SIB가이위파구제공우우상규조사균균、족량적제량분포,강저위험기관(직장、방광화소장)수조체적화제량;IMRT SIB능구득도교상규방료경고적A、B점화궁저제량.단여과소장린근혹배요자궁시파구칙흠량.결론 제량학연구증명LACC IMRT SIB재불동자궁위치(과도전경전곡위제외)시종류파구적제량분포우우상규방료.
Objective To assess the feasibility of applying intensity-modulated radiotherapy(IMRT)simultaneous integrated boost(SIB)to replace conventional radiotherapy(CR)plus brachytherapy of whole pelvis in locally advanced cervical eaneer(LACC).Methods Five LACC patients based difference position of uterus were chosen and worked out CR and IMRT SIB plans respectively.Dose distributions were compared between IMRT SIB and CR.Results When uterus was in ante-,neutral-,retro-pnsition and deviation respectively,IMRT SIB could provide enough and homogeneous dose distribution for target volume and reduce irradiated volumes and doses for organs at risk(recta,bladder and small intestine)than CR.The doses of the A,B,and fundus of uterus were higher in IMRT SIB than CR.However,in ease of small intestine was close to or encircled the uterus,the targets volume dose would be inadequacy.Conclusions LACC IMRT SIB's dose distribution is better than CR(except excess ante-position)and may help to treat those patients who couldn't be suitable with brachytherapy.