本文结合规范阐述了数据中心柴油系统与柴油发电机的重要性,介绍了数据中心柴油储存量的确定方法,图示了数据中,出柴油供应系统的做法,并简要描述了比较先进的柴油品质的监测、取样及维护做法。
本文結閤規範闡述瞭數據中心柴油繫統與柴油髮電機的重要性,介紹瞭數據中心柴油儲存量的確定方法,圖示瞭數據中,齣柴油供應繫統的做法,併簡要描述瞭比較先進的柴油品質的鑑測、取樣及維護做法。
본문결합규범천술료수거중심시유계통여시유발전궤적중요성,개소료수거중심시유저존량적학정방법,도시료수거중,출시유공응계통적주법,병간요묘술료비교선진적시유품질적감측、취양급유호주법。
This paper describes that diesel system and diesel generators are very important in data center according to the current codes. Methods of calculation on diesel storage volume are introduced. Diagram of diesel system are demonstrated by drawings. In addition, advanced technology on monitoring, sampling and maintenance of site-stored diesel are briefly described.