华西口腔医学杂志
華西口腔醫學雜誌
화서구강의학잡지
WEST CHINA JOURNAL OF STOMATOLOGY
2010年
1期
29-33
,共5页
谭发兵%王璐%付钢%吴树洪%金萍
譚髮兵%王璐%付鋼%吳樹洪%金萍
담발병%왕로%부강%오수홍%금평
适合性%光学印模%计算机辅助设计与制作%全瓷冠
適閤性%光學印模%計算機輔助設計與製作%全瓷冠
괄합성%광학인모%계산궤보조설계여제작%전자관
fit%optical impression%computer aided design/computer aided manufacture%all-ceramic crown
目的 研究Cerec 3D/Inlab MC XL系统不同光学印模法对Cerec Blocs全瓷冠边缘和内部适合性的影响.方法 制备1个右侧下颌第一磨牙全冠预备体模型,复制32个石膏代型.采用随机抽样法,16个代型用于冠粘接,16个代型用于光学印模采集,其中直接法和间接法各选取8个,分别制作8个Cerec Blocs全瓷冠.采用修正美国公共卫生服务(USPHS)标准和扫描电镜CSEM)法评价冠的适合性,SAS 9.1软件对实验数据进行统计分析.结果 修正USPHS法显示87.5%的边缘测试点临床可按受,直接法与间接法边缘适合性比较差异无统计学意义(P>0.05);SEM法显示所有冠的边缘测试点均小于120μm,直接法与间接法边缘和内部适合性比较差异均无统计学意义(P>0.05),但直接法在近中、颊面、舌面、骀面的适合性优于间接法(P<0.05);直接法远中轴面适合性较差,与近中轴面比较筹异有统计学意义(P<0.01).结论 光学印模法对Cerec Blocs冠边缘适合性无影响,但对内部适合性有一定影响,全瓷冠边缘适合性均在临床可接受范围内.
目的 研究Cerec 3D/Inlab MC XL繫統不同光學印模法對Cerec Blocs全瓷冠邊緣和內部適閤性的影響.方法 製備1箇右側下頜第一磨牙全冠預備體模型,複製32箇石膏代型.採用隨機抽樣法,16箇代型用于冠粘接,16箇代型用于光學印模採集,其中直接法和間接法各選取8箇,分彆製作8箇Cerec Blocs全瓷冠.採用脩正美國公共衛生服務(USPHS)標準和掃描電鏡CSEM)法評價冠的適閤性,SAS 9.1軟件對實驗數據進行統計分析.結果 脩正USPHS法顯示87.5%的邊緣測試點臨床可按受,直接法與間接法邊緣適閤性比較差異無統計學意義(P>0.05);SEM法顯示所有冠的邊緣測試點均小于120μm,直接法與間接法邊緣和內部適閤性比較差異均無統計學意義(P>0.05),但直接法在近中、頰麵、舌麵、駘麵的適閤性優于間接法(P<0.05);直接法遠中軸麵適閤性較差,與近中軸麵比較籌異有統計學意義(P<0.01).結論 光學印模法對Cerec Blocs冠邊緣適閤性無影響,但對內部適閤性有一定影響,全瓷冠邊緣適閤性均在臨床可接受範圍內.
목적 연구Cerec 3D/Inlab MC XL계통불동광학인모법대Cerec Blocs전자관변연화내부괄합성적영향.방법 제비1개우측하합제일마아전관예비체모형,복제32개석고대형.채용수궤추양법,16개대형용우관점접,16개대형용우광학인모채집,기중직접법화간접법각선취8개,분별제작8개Cerec Blocs전자관.채용수정미국공공위생복무(USPHS)표준화소묘전경CSEM)법평개관적괄합성,SAS 9.1연건대실험수거진행통계분석.결과 수정USPHS법현시87.5%적변연측시점림상가안수,직접법여간접법변연괄합성비교차이무통계학의의(P>0.05);SEM법현시소유관적변연측시점균소우120μm,직접법여간접법변연화내부괄합성비교차이균무통계학의의(P>0.05),단직접법재근중、협면、설면、태면적괄합성우우간접법(P<0.05);직접법원중축면괄합성교차,여근중축면비교주이유통계학의의(P<0.01).결론 광학인모법대Cerec Blocs관변연괄합성무영향,단대내부괄합성유일정영향,전자관변연괄합성균재림상가접수범위내.
Objective To study the effect of different optical impression methods in Cerec 3D/Inlab MC XL system on marginal and internal fit of all-ceramic crowns. Methods A right mandibular first molar in the standard model was used to prepare full crown and replicated into thirty-two plaster casts. Sixteen of them were selected randomly for bonding crown and the others were used for taking optical impression, in half of which the direct optical impres sion taking method were used and the others were used for the indirect method, and then eight Cerec Blocs all-ceramic crowns were manufactured respectively. The fit of all-ceramic crowns were evaluated by modified United States Public Health Service (USPHS) criteria and scanning electron microscope (SEM) imaging, and the data were statistically analyzed with SAS 9.1 software. Results The clinically acceptable rate for all marginal measurement sites was 87.5% according to USPHS criteria. There was no statistically significant difference in marginal fit between direct and indi rect method group (P>0.05). With SEM imaging, all marginal measurement sites were less than 120μm and no statistically significant difference was found between direct and indirect method group in terms of marginal or internal fit (P> 0.05). But the direct method group showed better fit than indirect method group in terms of mesial surface, lingual surface, buccal surface and occlusal surface (P<0.05). The distal surface's fit was worse and the obvious differ ence was observed between mesial surface and distal surface in direct method group (P<0.01). Conclusion Under the conditions of this study, the optical impression method had no significant effect on marginal fit of Cerec Blocs crowns, but it had certain effect on internal fit. Overall all-ceramic crowns appeared to have clinically acceptable marginal fit.