中华实验眼科杂志
中華實驗眼科雜誌
중화실험안과잡지
CHINESE JOURNAL OF EXPERIMENTAL OPHTHALMOLOGY
2011年
10期
918-921
,共4页
声学/超声生物显微镜/全景%前房%睫状沟%晶状体/人工%生物测量
聲學/超聲生物顯微鏡/全景%前房%睫狀溝%晶狀體/人工%生物測量
성학/초성생물현미경/전경%전방%첩상구%정상체/인공%생물측량
Acoustie/ultrasound biomicnoscopy/panoramic%Anterior chamber%Ciliary sulcus%Lens/intraocular%Bio-measurement
背景 睫状沟距离的直接测量对人工晶状体(I0L)植入术中IOL尺寸的选择具有重要意义.全景超声生物显微镜(UBM)的问世使在活体眼直接进行睫状沟距离的测量成为可能.目的 探讨人眼前房直径和睫状沟距离之间的相关性及其在不同前房深度人群中的差别.方法 将疑似青光眼患者30例30只右眼作为浅前房组,而具有高度近视(-7 ~-18 D)的30例30只右眼作为深前房组.应用全景超声生物显微镜(UBM)进行图像采集,每眼获取焦点位于虹膜平面的眼球水平方向3:00 ~9:00处的全景截面图像共3张.由同一测量者对每一幅图像的前房直径和睫状沟距离进行测量.取3幅图像测量值的均值为最终测量结果,用独立样本t检验和线性回归方程分析评估前房直径与睫状沟距离测量值的关系.结果 浅前房组的30眼中,全景UBM测得的前房直径为(11.49±0.75)mm,睫状沟距离为(10.97±0.86)mm,二者间的平均差值为(-5.14±0.55)mm,差异有统计学意义(t=-5.092,P=0.000),线性回归分析显示二者之间呈线性相关(R2=0.593,P=0.000),Pearson相关系数为0.767.深前房组的30眼中,全景UBM测得的前房直径均值为(12.69±0.67)mm;睫状沟距离为(12.31±0.61)mm,二者之间平均差值为(-0.38±0.17)mm,差异有统计学意义(t=-5.531,P=0.000);线性回归分析显示二者之间具有显著相关性(R2=0.699,P=0.000),Pearson相关系数为0.836.结论 全景UBM测得的睫状沟距离和前房直径呈明显正相关,深前房眼的相关性大于浅前房眼,该结果对于IOL植入术中IOL尺寸的选择具有重要意义.
揹景 睫狀溝距離的直接測量對人工晶狀體(I0L)植入術中IOL呎吋的選擇具有重要意義.全景超聲生物顯微鏡(UBM)的問世使在活體眼直接進行睫狀溝距離的測量成為可能.目的 探討人眼前房直徑和睫狀溝距離之間的相關性及其在不同前房深度人群中的差彆.方法 將疑似青光眼患者30例30隻右眼作為淺前房組,而具有高度近視(-7 ~-18 D)的30例30隻右眼作為深前房組.應用全景超聲生物顯微鏡(UBM)進行圖像採集,每眼穫取焦點位于虹膜平麵的眼毬水平方嚮3:00 ~9:00處的全景截麵圖像共3張.由同一測量者對每一幅圖像的前房直徑和睫狀溝距離進行測量.取3幅圖像測量值的均值為最終測量結果,用獨立樣本t檢驗和線性迴歸方程分析評估前房直徑與睫狀溝距離測量值的關繫.結果 淺前房組的30眼中,全景UBM測得的前房直徑為(11.49±0.75)mm,睫狀溝距離為(10.97±0.86)mm,二者間的平均差值為(-5.14±0.55)mm,差異有統計學意義(t=-5.092,P=0.000),線性迴歸分析顯示二者之間呈線性相關(R2=0.593,P=0.000),Pearson相關繫數為0.767.深前房組的30眼中,全景UBM測得的前房直徑均值為(12.69±0.67)mm;睫狀溝距離為(12.31±0.61)mm,二者之間平均差值為(-0.38±0.17)mm,差異有統計學意義(t=-5.531,P=0.000);線性迴歸分析顯示二者之間具有顯著相關性(R2=0.699,P=0.000),Pearson相關繫數為0.836.結論 全景UBM測得的睫狀溝距離和前房直徑呈明顯正相關,深前房眼的相關性大于淺前房眼,該結果對于IOL植入術中IOL呎吋的選擇具有重要意義.
배경 첩상구거리적직접측량대인공정상체(I0L)식입술중IOL척촌적선택구유중요의의.전경초성생물현미경(UBM)적문세사재활체안직접진행첩상구거리적측량성위가능.목적 탐토인안전방직경화첩상구거리지간적상관성급기재불동전방심도인군중적차별.방법 장의사청광안환자30례30지우안작위천전방조,이구유고도근시(-7 ~-18 D)적30례30지우안작위심전방조.응용전경초성생물현미경(UBM)진행도상채집,매안획취초점위우홍막평면적안구수평방향3:00 ~9:00처적전경절면도상공3장.유동일측량자대매일폭도상적전방직경화첩상구거리진행측량.취3폭도상측량치적균치위최종측량결과,용독립양본t검험화선성회귀방정분석평고전방직경여첩상구거리측량치적관계.결과 천전방조적30안중,전경UBM측득적전방직경위(11.49±0.75)mm,첩상구거리위(10.97±0.86)mm,이자간적평균차치위(-5.14±0.55)mm,차이유통계학의의(t=-5.092,P=0.000),선성회귀분석현시이자지간정선성상관(R2=0.593,P=0.000),Pearson상관계수위0.767.심전방조적30안중,전경UBM측득적전방직경균치위(12.69±0.67)mm;첩상구거리위(12.31±0.61)mm,이자지간평균차치위(-0.38±0.17)mm,차이유통계학의의(t=-5.531,P=0.000);선성회귀분석현시이자지간구유현저상관성(R2=0.699,P=0.000),Pearson상관계수위0.836.결론 전경UBM측득적첩상구거리화전방직경정명현정상관,심전방안적상관성대우천전방안,해결과대우IOL식입술중IOL척촌적선택구유중요의의.
Background Measurement of ciliary sulcus distance is important for phakic intraocular lens implantation.Suowei panoramic 50-MHz digital ultrasound biomicroscopy makes it possible for the direct measurement of ciliary sulcus distance.Objective The aim of this study was to investigate the correlation between anterior chamber(AC)angle diameter and ciliary sulcus distance in different AC depth population and offer a clinical guide.Methods The anterior chamber angle diameter and ciliary sulcus distance were measured in 30 right eyes with shallow anterior chamber caused by suspect glaucoma and 30 right eyes with deep anterior chamber dut to the high myopia with Suowei panoramic 50-MHz digital ultrasound biomicroscopy.Three horizontal B-scans with the focal plane approximately at a depth corresponding to the iris plane were acquired for each eye.The differences of the anterior chamber angle diameter and ciliary sulcus distance were calculated and compared between the two groups.The correlation of the anterior chamber angle diameter and ciliary sulcus distance were evaluated in respective group.Results In shallow AC group,the mean angle diameter was(11.49+0.75)mm,the mean ciliary sulcus distance was (10.97±0.86)mm with the mean standard deviation of the difference of(-5.14± 0.55)mm,showing a statistically significant difference(t =-5.092,P =0.000).In shallow AC group,linear regression analysis showed a statistically significant correlation between ciliary sulcus distance and angle diameter(R2=0.593,P=0.000)and the Pearson's correlation coefficient was 0.767.In deep AC group,the angle diameter was(12.69±0.67)mm;while ciliary sulcus distance was(12.31 ± 0.61)mm with the mean slandard deviation(-0.38 ± 0.17)mm,which was statistically significantly different(t=-5.531,P=0.000).The ciliary sulcus distance was found to be linear correlation with the angle diameter(R2 =0.699,P=0.000)and Pearson' s correlation coefficient of 0.836.Conclusions Panoramic ultrasound biomicroscopy is an useful tool to the measurement of ciliary sulcus distance.This study exhibited that the ciliary sulcus distance is significant associated with the anterior chamber angle diameter,which may offer a guide for phakic intraocular lens implantation.