国际检验医学杂志
國際檢驗醫學雜誌
국제검험의학잡지
INTERNATIONAL JOURNAL OF LABORATORY MEDICINE
2009年
5期
451-453
,共3页
李启欣%李炜煊%陈斌鸿%陈社安%李美珠
李啟訢%李煒煊%陳斌鴻%陳社安%李美珠
리계흔%리위훤%진빈홍%진사안%리미주
血糖%血尿素氮%临床实验室技术%评价研究
血糖%血尿素氮%臨床實驗室技術%評價研究
혈당%혈뇨소담%림상실험실기술%평개연구
Blood glucose%Blood urea nitrogen%Clinical laboratory techniques%Evalua-tion studies
目的 评价强生Vitros 950全自动干生化分析仪血清葡萄糖、尿素氮检测系统的精密度.方法 选择两个具有医学决定水平的人混合血清作为实验样品,每天分两批检测,每个样品重复测定两次,连续操作20 d,认真记录实验数据,计算批内不精密度(Sur)、批间不精密度(Srr)、日间不精密度(Sdd)和总不精密度(ST),并将Sur、Srr与1/4 CLlA'88进行比较,Sdd、ST与1/3 CLIA'88进行比较.结果 葡萄糖、尿素氮两个浓度的Sur,Srr<1/4 CLIA'88,Sdd、ST<1/3 CLIA'88.结论 强生Vitros 950全自动干生化分析仪血清葡萄糖、尿素氮检测系统具有良好的精密度,能满足临床的要求.
目的 評價彊生Vitros 950全自動榦生化分析儀血清葡萄糖、尿素氮檢測繫統的精密度.方法 選擇兩箇具有醫學決定水平的人混閤血清作為實驗樣品,每天分兩批檢測,每箇樣品重複測定兩次,連續操作20 d,認真記錄實驗數據,計算批內不精密度(Sur)、批間不精密度(Srr)、日間不精密度(Sdd)和總不精密度(ST),併將Sur、Srr與1/4 CLlA'88進行比較,Sdd、ST與1/3 CLIA'88進行比較.結果 葡萄糖、尿素氮兩箇濃度的Sur,Srr<1/4 CLIA'88,Sdd、ST<1/3 CLIA'88.結論 彊生Vitros 950全自動榦生化分析儀血清葡萄糖、尿素氮檢測繫統具有良好的精密度,能滿足臨床的要求.
목적 평개강생Vitros 950전자동간생화분석의혈청포도당、뇨소담검측계통적정밀도.방법 선택량개구유의학결정수평적인혼합혈청작위실험양품,매천분량비검측,매개양품중복측정량차,련속조작20 d,인진기록실험수거,계산비내불정밀도(Sur)、비간불정밀도(Srr)、일간불정밀도(Sdd)화총불정밀도(ST),병장Sur、Srr여1/4 CLlA'88진행비교,Sdd、ST여1/3 CLIA'88진행비교.결과 포도당、뇨소담량개농도적Sur,Srr<1/4 CLIA'88,Sdd、ST<1/3 CLIA'88.결론 강생Vitros 950전자동간생화분석의혈청포도당、뇨소담검측계통구유량호적정밀도,능만족림상적요구.
Objective To evaluate the precision of serum glucose (Glu) and blood urea nitrogen (Bun) measured by Johnson vitros 950 automatic dry-biochemical analyzer. Methods Two cases of hu-man pooled serum with medical decision levels were taken as experimental specimens. Detection was done twice a day on each speciment for 20 days. The experimental data were recorded carefully, and then the within-run imprecision, between-run imprecision, between-day imprecision and total impre-cision were calculated and compared with 1/4 CLIA'88 and 1/3 CLIA'88. Results The within-run im-precision, between-run imprecision of Glu and Bun in two levels were lower than 1/4 CLIA'88, while the between-day imprecision and total imprecision were lower than 1/3 CLIA' 88. Conclusion The Johnson vitros 950 automatic dry-biochemical analyzer possesses fine precision in Glu and Bun determi-nation,and can meet the clinical requirements.