中华检验医学杂志
中華檢驗醫學雜誌
중화검험의학잡지
CHINESE JOURNAL OF LABORATORY MEDICINE
2008年
8期
937-941
,共5页
血样采集%诊断设备%血小板活化%P选择素%生物相容性材料
血樣採集%診斷設備%血小闆活化%P選擇素%生物相容性材料
혈양채집%진단설비%혈소판활화%P선택소%생물상용성재료
Blood specimen collection%Diagnostic equipment%Platelet activation%P-selectin%Biocompatible materials
目的 研究人体静脉血样采集管的不同内表面状态对血小板活化的影响.方法 用聚环氧烷-聚二甲基硅氧烷共聚物(L722)、硅烷偶联剂对塑料管(PET)和玻璃管制膜,对L722玻璃管、L722 PET管、玻璃管、PET管、硅烷偶联剂制膜玻璃管及聚丙烯管(PP)内表面进行接触角分析.用上述材料的血样采集管采集血液标本并在室温下滚动混匀孵育110~60 min.用流式细胞术(FCM)检测血小板激活标志物CD62p.结果 不同材质及表面处理血液采集管的内表面的接触角大小在一定程度上反映了血小板活化率,但并不呈线性关系.PET管经L722表面改性后表达CD62p阳性的活化血小板百分率由(37.4±14.8)%下降到(21.9±12.4)%.玻璃管对表达CD62p阳性的活化血小板百分率为(54.5±18.6)%,明显大于PET管.玻璃管制膜后对血小板的激活明显减少,用硅烷偶联剂制膜的玻璃管表达CD62p阳性的活化血小板百分率为(28.3±8.2)%,明显低于L722制膜玻璃管.用PET作为基体材料经过L722表面处理后对血小板活化明显低于L722制膜的玻璃管的(41.5 ±15.9)%和用硅烷偶联剂制膜的玻璃管的(22.0±12.8)%.不同管对血小板活化时间进程显示:60 min L722 PET管和聚丙烯管的血小板活化与30 min的结果差异无统计学意义.结论 不同材质及表面处理血液盛装管所导致的不同表面能状态对血小板活化的影响有明显差异,硅油表面处理能有效改善血液采集管的血液相容性.FCM检测CD62p是评价血液收集管材料介导的血小板活化的灵敏指标,对建立血液盛装材料表面处理模型及筛选临床应用材料具有重要意义.
目的 研究人體靜脈血樣採集管的不同內錶麵狀態對血小闆活化的影響.方法 用聚環氧烷-聚二甲基硅氧烷共聚物(L722)、硅烷偶聯劑對塑料管(PET)和玻璃管製膜,對L722玻璃管、L722 PET管、玻璃管、PET管、硅烷偶聯劑製膜玻璃管及聚丙烯管(PP)內錶麵進行接觸角分析.用上述材料的血樣採集管採集血液標本併在室溫下滾動混勻孵育110~60 min.用流式細胞術(FCM)檢測血小闆激活標誌物CD62p.結果 不同材質及錶麵處理血液採集管的內錶麵的接觸角大小在一定程度上反映瞭血小闆活化率,但併不呈線性關繫.PET管經L722錶麵改性後錶達CD62p暘性的活化血小闆百分率由(37.4±14.8)%下降到(21.9±12.4)%.玻璃管對錶達CD62p暘性的活化血小闆百分率為(54.5±18.6)%,明顯大于PET管.玻璃管製膜後對血小闆的激活明顯減少,用硅烷偶聯劑製膜的玻璃管錶達CD62p暘性的活化血小闆百分率為(28.3±8.2)%,明顯低于L722製膜玻璃管.用PET作為基體材料經過L722錶麵處理後對血小闆活化明顯低于L722製膜的玻璃管的(41.5 ±15.9)%和用硅烷偶聯劑製膜的玻璃管的(22.0±12.8)%.不同管對血小闆活化時間進程顯示:60 min L722 PET管和聚丙烯管的血小闆活化與30 min的結果差異無統計學意義.結論 不同材質及錶麵處理血液盛裝管所導緻的不同錶麵能狀態對血小闆活化的影響有明顯差異,硅油錶麵處理能有效改善血液採集管的血液相容性.FCM檢測CD62p是評價血液收集管材料介導的血小闆活化的靈敏指標,對建立血液盛裝材料錶麵處理模型及篩選臨床應用材料具有重要意義.
목적 연구인체정맥혈양채집관적불동내표면상태대혈소판활화적영향.방법 용취배양완-취이갑기규양완공취물(L722)、규완우련제대소료관(PET)화파리관제막,대L722파리관、L722 PET관、파리관、PET관、규완우련제제막파리관급취병희관(PP)내표면진행접촉각분석.용상술재료적혈양채집관채집혈액표본병재실온하곤동혼균부육110~60 min.용류식세포술(FCM)검측혈소판격활표지물CD62p.결과 불동재질급표면처리혈액채집관적내표면적접촉각대소재일정정도상반영료혈소판활화솔,단병불정선성관계.PET관경L722표면개성후표체CD62p양성적활화혈소판백분솔유(37.4±14.8)%하강도(21.9±12.4)%.파리관대표체CD62p양성적활화혈소판백분솔위(54.5±18.6)%,명현대우PET관.파리관제막후대혈소판적격활명현감소,용규완우련제제막적파리관표체CD62p양성적활화혈소판백분솔위(28.3±8.2)%,명현저우L722제막파리관.용PET작위기체재료경과L722표면처리후대혈소판활화명현저우L722제막적파리관적(41.5 ±15.9)%화용규완우련제제막적파리관적(22.0±12.8)%.불동관대혈소판활화시간진정현시:60 min L722 PET관화취병희관적혈소판활화여30 min적결과차이무통계학의의.결론 불동재질급표면처리혈액성장관소도치적불동표면능상태대혈소판활화적영향유명현차이,규유표면처리능유효개선혈액채집관적혈액상용성.FCM검측CD62p시평개혈액수집관재료개도적혈소판활화적령민지표,대건립혈액성장재료표면처리모형급사선림상응용재료구유중요의의.
Objective To study the effects of different inner face status of human venous blood container on platelet activation. Methods The plastic( polyethene terephthalate,PET) and glass tubes were coated with polyalkyleneoxide modified polydimethylsiloxane(L722). The contact angles of L722-coated glass and L722- coated PET tubes, glass tubes, PET tubes, silane coupling agent-coated glass tubes and polypropylene (PP) tubes were analyzed respectively. The blood were drawn into above tubes, and then incubated in a roller bottle at room temperature for 10-60 mira The marker of activated platelete, CD62p, was detected by flow cytometry(FCM). Results The inner face contact angle of the blood collection tubes with different material and surface treatment reflected platelet activation to a certain extent, but was not linear. The percent age of CD62p positive platelets in L722-modified PET tubes reduced from (37.4 ±14. 8) % to(21.9 ± 12. 4) %. The platelet activation by glass tubes was (54.5 ± 18.6 ) %, markedly more than PET tubes. While membrane formed, the platelet activation by glass tubes decreased remarkably, and the percentage of CD62p positive platelet in silane coupling agent-coated glass tubes were ( 28. 3 ± 8.2 ) %,markedly less than that of the L722-coated glass tubes. The platelet activation by PET-based material ectally modified with L722 was obviously less than L722-coated glass tubes and the percentage of CD62p positive platelet in silane coupling agent-coated glass tubes were ( 41.5 ± 15.9 ) % and ( 22. 0 ± 12. 8 ) %,respectively. The time course of platelet activation by different tubes showed that the platelet activation by L722-coated PET tubes and polypropylene tubes in 60 rain was not significantly different from the results in30 mitt Conclusions The diverse surface energy status induced by different material and surface treatment of blood collection tubes have obvious effects on the activation of platelets. The silicic oil surface treatment can effectively improve the blood compatibility of blood collection tubes. CD62p detectod by FCM is a sensitive marker for the evaluation of the activation of platelets induced by the material of blood collection tubes. It is of importance in the establishment of surface treatment model of blood container and screening out the material of clinical application.