中南大学学报(英文版)
中南大學學報(英文版)
중남대학학보(영문판)
JOURNAL OF CENTRAL SOUTH UNIVERSITY OF TECHNOLOGY(ENGLISH EDITION)
2012年
9期
2578-2583
,共6页
oscillating heat pipe%pressure fluctuation%heat flow resistance%filling ratio
The pressure characteristics inside single loop oscillating heat pipe (OHP) having 4.5 mm inner diameter copper tube with the loop height of 440 mm were addressed.Distilled water was used as working fluid inside the OHP with different filling ratios of 40%,60% and 80% of total inside volume.Experimental results show that the thermal characteristics are significantly inter-related with pressure fluctuations as well as pressure frequency.And the pressure frequency also depends upon the evaporator temperature that is maintained in the range of 60-96 ℃.Piezoresistive absolute pressure sensor (Model-Kistler 4045A5) was used to take data.The investigation shows that the filling ratio of 60% gives the highest inside pressure magnitude at maximum number of pressure frequency at any of set evaporator temperature and the lowest heat flow resistance is achieved at 60% filling ratio.