目的探讨宝石CT冠状动脉成像技术(GCTA)对诊断糖调节受损(IGR)患者冠状动脉狭窄改变的临床应用价值。方法27例空腹血糖受损(IFG)和34例糖耐量受损(IGT)患者行GCTA后1个月内行选择性冠状动脉造影(CAG),以CAG为标准,评价GCTA诊断冠脉管腔狭窄≥50%的准确率、灵敏度(Se)、特异度(Sp)、阳性预测值(PPV)、阴性预测值(NPV)。结果86支冠状动脉管腔狭窄≥50%(占35.3%),其中单支5例(8.2%),2支21例(34.4%),3支以上11例(18.0%)。宝石CT诊断冠脉狭窄≥50%的准确率、Se、Sp、PPV、NPV分别为94.5%、87.9%、96.1%、93.0%和92.9%。结论宝GCTA作为一种无创性检查,对糖尿病前期冠状动脉狭窄的检测有较高准确性。处于糖尿病前期阶段并存在1个以上其他冠心病危险因素时就应开始GCTA筛查。
目的探討寶石CT冠狀動脈成像技術(GCTA)對診斷糖調節受損(IGR)患者冠狀動脈狹窄改變的臨床應用價值。方法27例空腹血糖受損(IFG)和34例糖耐量受損(IGT)患者行GCTA後1箇月內行選擇性冠狀動脈造影(CAG),以CAG為標準,評價GCTA診斷冠脈管腔狹窄≥50%的準確率、靈敏度(Se)、特異度(Sp)、暘性預測值(PPV)、陰性預測值(NPV)。結果86支冠狀動脈管腔狹窄≥50%(佔35.3%),其中單支5例(8.2%),2支21例(34.4%),3支以上11例(18.0%)。寶石CT診斷冠脈狹窄≥50%的準確率、Se、Sp、PPV、NPV分彆為94.5%、87.9%、96.1%、93.0%和92.9%。結論寶GCTA作為一種無創性檢查,對糖尿病前期冠狀動脈狹窄的檢測有較高準確性。處于糖尿病前期階段併存在1箇以上其他冠心病危險因素時就應開始GCTA篩查。
목적탐토보석CT관상동맥성상기술(GCTA)대진단당조절수손(IGR)환자관상동맥협착개변적림상응용개치。방법27례공복혈당수손(IFG)화34례당내량수손(IGT)환자행GCTA후1개월내행선택성관상동맥조영(CAG),이CAG위표준,평개GCTA진단관맥관강협착≥50%적준학솔、령민도(Se)、특이도(Sp)、양성예측치(PPV)、음성예측치(NPV)。결과86지관상동맥관강협착≥50%(점35.3%),기중단지5례(8.2%),2지21례(34.4%),3지이상11례(18.0%)。보석CT진단관맥협착≥50%적준학솔、Se、Sp、PPV、NPV분별위94.5%、87.9%、96.1%、93.0%화92.9%。결론보GCTA작위일충무창성검사,대당뇨병전기관상동맥협착적검측유교고준학성。처우당뇨병전기계단병존재1개이상기타관심병위험인소시취응개시GCTA사사。
Objective To describe and analyze the appearance of coronary artery in patients with impaired glucose regulation(IGR)by using the gemstone spectral CT,and to explore the indications and value for Gemstone Computed Tomography Angiography. Methods 27 patients with impaired fasting glucose(IFG)and 34 patients with impaired glucose tolerance(IGT)underwent gemstone computed tomography angiography(GCTA).All patients received selective coronary angiography within 1 month after GCTA.The CT appearances of coronary artery in patients with impaired glucose regulation were evaluated and analyzed.The coronary angiography results were served as standard to evaluate the diagnostic accuracy、Se、Sp、PPV、NPV of GCTA. Results Significant coronary stenosis was detected in 86(35.3%)from all the 243 coronary arteries of patients enrolled,among whom,5(8.2%)were with single branch lesion,21(34.4%)with double branch lesions,and 11(18.0%)with multiple branch lesions. The accuracy rate,sensitivity,specificity,positive and negative predictive values of GCTA for detection of significant stenosis in patients with IGR were 94.5%、87.9%、96.1%、93.0% and 92.9% respectively. Conclusion As a non-invasive examination,gemstone computed tomography angiography is rather accurate in identifying coronary artery lesions of patients with IGR.Screening with GCTA is indicated for patients with IGR who have at least one risk factor for coronary artery disease.