目的 探讨不同能量氩离子激光防止翼状胬肉术后复发的效果.方法 将116例116只眼原发性翼状胬肉术后1周手术区结膜或角膜缘出现新生血管胚芽的患者分为3组:(1)低能量氩离子激光光凝组(A组)56例,功率0.1~0.15 W;(2)常规能量氩离子激光光凝组(B组)30例,功率0.2~0.3 W;(3)对照组(C组)30例,不行光凝.结果 随访1年,A、B、C组胬肉术后复发率分别为7.1%、10.0%、33.3%.激光治疗后A组患者结膜充血、结膜灼伤、结膜充血的发生率均低于B组(P<0.05).结论 低能量氩离子激光照射封闭胬肉术后1周新生血管胚芽,为防止翼状胬肉术后复发的一种有效方法,激光治疗后胬肉早期新生血管胚芽、结膜灼伤、结膜出血等局部反应较少.
目的 探討不同能量氬離子激光防止翼狀胬肉術後複髮的效果.方法 將116例116隻眼原髮性翼狀胬肉術後1週手術區結膜或角膜緣齣現新生血管胚芽的患者分為3組:(1)低能量氬離子激光光凝組(A組)56例,功率0.1~0.15 W;(2)常規能量氬離子激光光凝組(B組)30例,功率0.2~0.3 W;(3)對照組(C組)30例,不行光凝.結果 隨訪1年,A、B、C組胬肉術後複髮率分彆為7.1%、10.0%、33.3%.激光治療後A組患者結膜充血、結膜灼傷、結膜充血的髮生率均低于B組(P<0.05).結論 低能量氬離子激光照射封閉胬肉術後1週新生血管胚芽,為防止翼狀胬肉術後複髮的一種有效方法,激光治療後胬肉早期新生血管胚芽、結膜灼傷、結膜齣血等跼部反應較少.
목적 탐토불동능량아리자격광방지익상노육술후복발적효과.방법 장116례116지안원발성익상노육술후1주수술구결막혹각막연출현신생혈관배아적환자분위3조:(1)저능량아리자격광광응조(A조)56례,공솔0.1~0.15 W;(2)상규능량아리자격광광응조(B조)30례,공솔0.2~0.3 W;(3)대조조(C조)30례,불행광응.결과 수방1년,A、B、C조노육술후복발솔분별위7.1%、10.0%、33.3%.격광치료후A조환자결막충혈、결막작상、결막충혈적발생솔균저우B조(P<0.05).결론 저능량아리자격광조사봉폐노육술후1주신생혈관배아,위방지익상노육술후복발적일충유효방법,격광치료후노육조기신생혈관배아、결막작상、결막출혈등국부반응교소.
Objective To explore the effect of diffrent-energy argon laser on preventing the postoperative recurrence of pterygium. Methods A total of 116 cases(116 eyes) with new vessels appearing in surgery site of cornea and/or conjunctivae one week after undergoing pterygium excision were divided into 3 groups; group A(56 cases,56 eyes) received low-energy argon laser photocoagulation, power; 0.1-0.15 W; group B (30 cases, 30 eyes) received normal-energy argon laser photocoagulation, power 0. 2-0. 3 W; group C (30 cases,30 eyes) didnt receive any argon laser photocoagulation.Results After one year follow-up, the rate of postoperative recurrence of three groups was 1.1% , 10.0% and 33.3% , respectively. As compared with group C, the rate of postoperative recurrence of groups A and B was significantly decreased (P<0.05 and <0. 01, respectively). As compared with group B, the rate of postoperative recurrence of group A was not significantly changed (P>0.05) ; but the complications of conjunctive bum and hemorrhage in group A were significantly decreased (P<0.05).Conclusions Using argon laser to coagulate new vessels can reduce the postoperative recurrence rate the of pterygium. And low-energy argon laser can reduce the complications of photocoagulation, its an effective and safe treatment in preventing the postoperative recurrence of pterygium.