厌氧氨氧化(ANAMMOX)工艺是一种新型生物脱氮工艺,具有良好的应用前景.但ANAMMOX以亚硝酸盐为电子受体,需与短程硝化(SHARON)联合应用.SHARON是一个产酸反应,而ANAMMOX是一个嗜碱反应,后者会受前者的干扰.试验结果表明,低进水pH冲击对高负荷(总氮负荷9.3~27.7 kg·(m~3·d)~(-1)ANAMMOX反应器效能具有显著影响.在一定范围内,提高总氮负荷可削弱低进水pH冲击的影响,设置回流也可缓解低进水pH冲击所致的负面效应.低进水pH冲击对厌氧氨氧化反应器效能的影响主要来自低pH与游离亚硝酸毒性的双重抑制,其中低pH的直接作用对反应器效能的影响更大.低进水pH冲击所致的反应器效能恶化可采用停车自然恢复、清水冲洗恢复和外加碱液恢复.
厭氧氨氧化(ANAMMOX)工藝是一種新型生物脫氮工藝,具有良好的應用前景.但ANAMMOX以亞硝痠鹽為電子受體,需與短程硝化(SHARON)聯閤應用.SHARON是一箇產痠反應,而ANAMMOX是一箇嗜堿反應,後者會受前者的榦擾.試驗結果錶明,低進水pH遲擊對高負荷(總氮負荷9.3~27.7 kg·(m~3·d)~(-1)ANAMMOX反應器效能具有顯著影響.在一定範圍內,提高總氮負荷可削弱低進水pH遲擊的影響,設置迴流也可緩解低進水pH遲擊所緻的負麵效應.低進水pH遲擊對厭氧氨氧化反應器效能的影響主要來自低pH與遊離亞硝痠毒性的雙重抑製,其中低pH的直接作用對反應器效能的影響更大.低進水pH遲擊所緻的反應器效能噁化可採用停車自然恢複、清水遲洗恢複和外加堿液恢複.
염양안양화(ANAMMOX)공예시일충신형생물탈담공예,구유량호적응용전경.단ANAMMOX이아초산염위전자수체,수여단정초화(SHARON)연합응용.SHARON시일개산산반응,이ANAMMOX시일개기감반응,후자회수전자적간우.시험결과표명,저진수pH충격대고부하(총담부하9.3~27.7 kg·(m~3·d)~(-1)ANAMMOX반응기효능구유현저영향.재일정범위내,제고총담부하가삭약저진수pH충격적영향,설치회류야가완해저진수pH충격소치적부면효응.저진수pH충격대염양안양화반응기효능적영향주요래자저pH여유리아초산독성적쌍중억제,기중저pH적직접작용대반응기효능적영향경대.저진수pH충격소치적반응기효능악화가채용정차자연회복、청수충세회복화외가감액회복.
Anaerobic ammonia oxidation (ANAMMOX) process is a new biotechnology for nitrogen removal and is promising in the wastewater treatment engineering. However, it should be combined with SHARON (single reactor high activity ammonia removal over nitrite) process because it needs nitrite released from the latter process. The performance of ANAMMOX process could be interfered by the low pH of effluent from SHARON process. The results show that the low pH shock has serious influence on the performance of ANAMMOX reactor with total nitrogen loading rate (NLR) between 9.3~27.7 kg·(m~3·d)~(-1). But the influence of low pH shock could be alleviated by using recirculation or higher nitrogen loading rate. The effect of low pH on ANAMMOX reactor is mainly caused by the inhibitions of acidity and free nitrous acid, between them, the inhibition of acidity is even more serious. It was proved that, according to the injured degree, the performance of the ANAMMOX reactor deteriorated by low pH shock can be restored by taking strategies of stopping the feeding of the reactor, flushing the reactor with fresh water, and adding alkali solution into the reactor, respectively.