目的 探讨长回波时间(TE)的点解析波谱序列(PRESS)外标准和线性拟合模型(LCModel)定量检测活体脑肌酸(Cr)浓度的准确性.方法 10头2周龄猪及1个外标准模型用于本次实验.氢质子MR波谱(1H-MRS)实验采用GE 1.5 T MR扫描仪及标准正交头线圈.感兴趣区大小为2 cm×2 cm×2 cm,分别定位于动物脑和外标准溶液.PRESS序列按TE 135 ms,TR 1500 ms,128次扫描,获得感兴趣区Cr的波谱数据,然后用LCModel分析活体脑Cr浓度.每只动物做完MRS检查后即刻处死,用高效液相色谱方法(HPLC)分析离体脑Cr浓度.采用配对样本t检验比较活体和离体检测结果的差别.结果 1H-MRS测定的活体脑Cr浓度为(9.37±0.14)mmol/kg,HPLC测定的离体脑Cr浓度为(8.91±0.13)mmol/kg,两种方法的检测结果差异无统计学意义(t=9.038,P=0.491).结论 长TE的PRESS序列外标准结合LCModel可以准确无创地定量检测活体脑Cr浓度.
目的 探討長迴波時間(TE)的點解析波譜序列(PRESS)外標準和線性擬閤模型(LCModel)定量檢測活體腦肌痠(Cr)濃度的準確性.方法 10頭2週齡豬及1箇外標準模型用于本次實驗.氫質子MR波譜(1H-MRS)實驗採用GE 1.5 T MR掃描儀及標準正交頭線圈.感興趣區大小為2 cm×2 cm×2 cm,分彆定位于動物腦和外標準溶液.PRESS序列按TE 135 ms,TR 1500 ms,128次掃描,穫得感興趣區Cr的波譜數據,然後用LCModel分析活體腦Cr濃度.每隻動物做完MRS檢查後即刻處死,用高效液相色譜方法(HPLC)分析離體腦Cr濃度.採用配對樣本t檢驗比較活體和離體檢測結果的差彆.結果 1H-MRS測定的活體腦Cr濃度為(9.37±0.14)mmol/kg,HPLC測定的離體腦Cr濃度為(8.91±0.13)mmol/kg,兩種方法的檢測結果差異無統計學意義(t=9.038,P=0.491).結論 長TE的PRESS序列外標準結閤LCModel可以準確無創地定量檢測活體腦Cr濃度.
목적 탐토장회파시간(TE)적점해석파보서렬(PRESS)외표준화선성의합모형(LCModel)정량검측활체뇌기산(Cr)농도적준학성.방법 10두2주령저급1개외표준모형용우본차실험.경질자MR파보(1H-MRS)실험채용GE 1.5 T MR소묘의급표준정교두선권.감흥취구대소위2 cm×2 cm×2 cm,분별정위우동물뇌화외표준용액.PRESS서렬안TE 135 ms,TR 1500 ms,128차소묘,획득감흥취구Cr적파보수거,연후용LCModel분석활체뇌Cr농도.매지동물주완MRS검사후즉각처사,용고효액상색보방법(HPLC)분석리체뇌Cr농도.채용배대양본t검험비교활체화리체검측결과적차별.결과 1H-MRS측정적활체뇌Cr농도위(9.37±0.14)mmol/kg,HPLC측정적리체뇌Cr농도위(8.91±0.13)mmol/kg,량충방법적검측결과차이무통계학의의(t=9.038,P=0.491).결론 장TE적PRESS서렬외표준결합LCModel가이준학무창지정량검측활체뇌Cr농도.
Objective To investigate the accuracy for absolute quantification of brain creatine (Cr) concentration using long time echo (TE) point resolved spectroscopy (PRESS) sequence performed with an external standard and postprocessed with the linear combination of model spectra (LCModel).Methods Ten swine (3.1±0.6 kg) and an external standard phantom containing detectable compounds of known concentration were investigated in this study by using 1.5 T GE Signa scanner and a standard head coil. The single-voxel proton magnetic resonance spectroscopy (1H-MRS) data were acquired from the two ROIs (2 cm×2 cm×2 cm) placed in swine brain and external standard solution using PRESS sequence with TE 135 ms,TR 1500 ms,and 128 scan averages.The in vivo quantification of Cr was accomplished by LCModel.After 1H-MRS examination,each animal was sacrificed immediately.In vitro Cr concentration was analyzed by high performance liquid chromatography (HPLC).Results In the 1H-MRS group,the Cr concentration was (9.37±0.14)mmol/kg.In the HPLC group,the Cr concentration was (8.91±0.13)mmol/kg.Good agreement was obtained between these two methods (t=9.038,P=0.491).Conclusion The long echo time PRESS sequence performed with an external standard and processed with LCModel iS proven to be an accurate technique to detect the in vivo brain Cr concentration.