由于区域电网的互联,整个系统的惯性时间常数将会发生明显变化,继而会影响整网的暂态稳定水平。基于暂态能量函数法,通过对等值2机系统进行数学推导并作暂态稳定分析,研究了系统在各种运行方式下,2端机组惯量变化对电力系统暂态稳定水平产生的影响,比较了两端机组惯量变化分别对系统暂态稳定性的影响,并发现了系统机组惯性时间常数对系统暂态稳定水平造成的影响与系统的负荷水平及初始工况有关。在理论分析的基础上,结合相关算例在各种运行方式下进行了仿真研究,仿真结果验证了分析结果的正确性。
由于區域電網的互聯,整箇繫統的慣性時間常數將會髮生明顯變化,繼而會影響整網的暫態穩定水平。基于暫態能量函數法,通過對等值2機繫統進行數學推導併作暫態穩定分析,研究瞭繫統在各種運行方式下,2耑機組慣量變化對電力繫統暫態穩定水平產生的影響,比較瞭兩耑機組慣量變化分彆對繫統暫態穩定性的影響,併髮現瞭繫統機組慣性時間常數對繫統暫態穩定水平造成的影響與繫統的負荷水平及初始工況有關。在理論分析的基礎上,結閤相關算例在各種運行方式下進行瞭倣真研究,倣真結果驗證瞭分析結果的正確性。
유우구역전망적호련,정개계통적관성시간상수장회발생명현변화,계이회영향정망적잠태은정수평。기우잠태능량함수법,통과대등치2궤계통진행수학추도병작잠태은정분석,연구료계통재각충운행방식하,2단궤조관량변화대전력계통잠태은정수평산생적영향,비교료량단궤조관량변화분별대계통잠태은정성적영향,병발현료계통궤조관성시간상수대계통잠태은정수평조성적영향여계통적부하수평급초시공황유관。재이론분석적기출상,결합상관산례재각충운행방식하진행료방진연구,방진결과험증료분석결과적정학성。
Due to the interconnection of regional power grids, the inertia time constant of the whole interconnected grid evidently changes, then transient stability level of the interconnected power grid will be influenced. Based on transient energy function, by means of mathematical deduce for equivalent two-machine system and analysis on its transient stability, the influences of unit inertial changes at both terminals on transient stability level of the whole system under various operation modes are researched, and respective influences of terminal unit inertial changes on transient stability of the whole grid are compared, besides, it is found that the influences of unit inertial time constants on system transient stability level are relevant to load level and initial operating condition of the power grid. Based on theoretical analysis, simulation of concerned examples under various operation modes is performed and the correctness of theoretical analysis results is verified by simulation results.