某600MW亚临界机组于2006年投产,机组运行过程中发现,磨煤机性能比同类型机组略差,本文对制粉系统的煤粉细度、粉管风量偏差、制粉系统单耗、阻力等参数进行了试验,提出相应的改进措施和建议,为锅炉提高经济效益提供参考。
某600MW亞臨界機組于2006年投產,機組運行過程中髮現,磨煤機性能比同類型機組略差,本文對製粉繫統的煤粉細度、粉管風量偏差、製粉繫統單耗、阻力等參數進行瞭試驗,提齣相應的改進措施和建議,為鍋爐提高經濟效益提供參攷。
모600MW아림계궤조우2006년투산,궤조운행과정중발현,마매궤성능비동류형궤조략차,본문대제분계통적매분세도、분관풍량편차、제분계통단모、조력등삼수진행료시험,제출상응적개진조시화건의,위과로제고경제효익제공삼고。
A 600MW Subcritical Units put into operation in 2006, during the operation of the unit, performance of Coal mill is slightly worse than the same type unit, In order to solve the problem, the fineness of pulverized coal, the differ-ence of powder tube quantity, consumption of pulverizing system, resistance and other parameters of pulverizing system is tested, corresponding improvement measures and recommendations is provided for improve economic benefit of boiler.