对四川什邡市某水厂臭氧-生物活性炭(O3/BAC)深度处理工艺进行分析,阐述了O3/BAC工艺的工程经验和措施,具体工艺方案为:在有空气分离制氧企业的城市,当臭氧耗量Q≤60 kgO3/h时选择外购液氧,反之可考虑现场空气分离制氧;预臭氧氧化效果与O3加注量Q的相关性大于接触时间T的影响,若原水需杀藻,T建议≥5 min;主臭氧接触池三段式最佳投加比例为4∶3∶3,控制CT值(CT≥4 min? mg/L)对杀灭“两虫”有表征意义;活性炭吸附与结构性能的关键指标建议值为:碘值≥900 mg? g-1,亚甲兰值≥150 mg? g-1,比表面积≥1000 m 2?g-1,总孔容积≥0.6 cc? g-1;炭滤池上设透光密封罩,炭层下增加500 mm砂层,并降低设计滤速对保障运行安全、降低微生物穿透滤层的风险有利。
對四川什邡市某水廠臭氧-生物活性炭(O3/BAC)深度處理工藝進行分析,闡述瞭O3/BAC工藝的工程經驗和措施,具體工藝方案為:在有空氣分離製氧企業的城市,噹臭氧耗量Q≤60 kgO3/h時選擇外購液氧,反之可攷慮現場空氣分離製氧;預臭氧氧化效果與O3加註量Q的相關性大于接觸時間T的影響,若原水需殺藻,T建議≥5 min;主臭氧接觸池三段式最佳投加比例為4∶3∶3,控製CT值(CT≥4 min? mg/L)對殺滅“兩蟲”有錶徵意義;活性炭吸附與結構性能的關鍵指標建議值為:碘值≥900 mg? g-1,亞甲蘭值≥150 mg? g-1,比錶麵積≥1000 m 2?g-1,總孔容積≥0.6 cc? g-1;炭濾池上設透光密封罩,炭層下增加500 mm砂層,併降低設計濾速對保障運行安全、降低微生物穿透濾層的風險有利。
대사천십방시모수엄취양-생물활성탄(O3/BAC)심도처리공예진행분석,천술료O3/BAC공예적공정경험화조시,구체공예방안위:재유공기분리제양기업적성시,당취양모량Q≤60 kgO3/h시선택외구액양,반지가고필현장공기분리제양;예취양양화효과여O3가주량Q적상관성대우접촉시간T적영향,약원수수살조,T건의≥5 min;주취양접촉지삼단식최가투가비례위4∶3∶3,공제CT치(CT≥4 min? mg/L)대살멸“량충”유표정의의;활성탄흡부여결구성능적관건지표건의치위:전치≥900 mg? g-1,아갑란치≥150 mg? g-1,비표면적≥1000 m 2?g-1,총공용적≥0.6 cc? g-1;탄려지상설투광밀봉조,탄층하증가500 mm사층,병강저설계려속대보장운행안전、강저미생물천투려층적풍험유리。
Ozone-Biological Activated Carbon (BAC/O3 ) process design was introduced in one first bulited water treatmen plant in Shifang Shichuan China.This paper discussed the experience and measures for O 3/BAC technology project.If the thecholgy for separa-ting oxygen from air was provided in project location , when the ozone consumption Q o3≤60 kgo3/h , purchase of liquid oxygen as the raw material would be more economical , when Qo3 >60 kgo3/h, adopting the separated oxygen from air whould be better .In pre-ozona-tion reactor, O3 charging quantity Q had more effect on the ozone oxidation effect than contact time T ,but if the raw water needed to kill alga, adviced T≥5 min;In post-ozonation reactor,usually divided into three phases , the best dosing ratio was 4∶3∶3,and the CT value (CT≥4 min? mg/L) had representation meaning to kill “two bug”.The key indicators value of the Activated carbon adsorption and structure properties were introduced:iodine value was 900 mg? g-1 , and JiaLan value was 150 mg? g-1 , or specific surface area of 1000 1000 m 2? g-1 , total pore volume was 0.6 cc? g-1 , etc.; The light seal cover should be bulited above carbon filter , 500 mm sand was added under the carbon layer and design filter speed should be reduced to ensure safety operation and reduce the risk of mi -crobial penetration filter layer.