建立了用气相色谱仪和硫化学发光检测器检测高含硫天然气中硫化合物的方法。运用微流控制器解决了高浓度H2 S对检测器的污染以及对其他硫化合物测定的干扰问题,只需一种标准物质就可快速经济地完成高含硫天然气中多种硫化合物测定。该方法根据标准物质的保留时间完成多种硫化合物的定性,并用外标法定量。用该方法进行高含硫天然气样品测定,硫含量和色谱峰面积呈明显的线性关系,线性相关系数 r为0.9997。测定质量浓度为2 mg/m3以下的硫化合物时,测定结果的相对标准偏差小于6.1%;测定质量浓度为2 m g/m3以上的硫化合物时,测定结果的相对标准偏差小于2.2%,满足高含硫天然气的分析需要。
建立瞭用氣相色譜儀和硫化學髮光檢測器檢測高含硫天然氣中硫化閤物的方法。運用微流控製器解決瞭高濃度H2 S對檢測器的汙染以及對其他硫化閤物測定的榦擾問題,隻需一種標準物質就可快速經濟地完成高含硫天然氣中多種硫化閤物測定。該方法根據標準物質的保留時間完成多種硫化閤物的定性,併用外標法定量。用該方法進行高含硫天然氣樣品測定,硫含量和色譜峰麵積呈明顯的線性關繫,線性相關繫數 r為0.9997。測定質量濃度為2 mg/m3以下的硫化閤物時,測定結果的相對標準偏差小于6.1%;測定質量濃度為2 m g/m3以上的硫化閤物時,測定結果的相對標準偏差小于2.2%,滿足高含硫天然氣的分析需要。
건립료용기상색보의화류화학발광검측기검측고함류천연기중류화합물적방법。운용미류공제기해결료고농도H2 S대검측기적오염이급대기타류화합물측정적간우문제,지수일충표준물질취가쾌속경제지완성고함류천연기중다충류화합물측정。해방법근거표준물질적보류시간완성다충류화합물적정성,병용외표법정량。용해방법진행고함류천연기양품측정,류함량화색보봉면적정명현적선성관계,선성상관계수 r위0.9997。측정질량농도위2 mg/m3이하적류화합물시,측정결과적상대표준편차소우6.1%;측정질량농도위2 m g/m3이상적류화합물시,측정결과적상대표준편차소우2.2%,만족고함류천연기적분석수요。
The method was established for determination of sulfur compounds in high sour natural gas by gas chromatography with sulfur chemiluminescent detector .The pollution to de-tector and interference from high concentration H 2 S has been solved by using micro flow control-ler .A fast and economical method has been established to detect several sulfides in sulfur-bearing natural gas with only one standard material .The qualitative analysis of sulfides was performed according to retention time of standard material and the quantitative analysis was performed on the basis of External Standard Method .The linear relationship between sulfur content and chro-matographic peak area is obvious with this method for testing high sulfur natural gas sample and the correlation coefficient r was 0 .999 7 .The relative standard deviation for sulfides under the concentration of 2 mg/m3 was less than 6 .1% ,and that of the sample with the concentration a-bove 2 mg/m3 was less than 2 .2% .The methods can completely meet the needs to analyze the high sulfur natural gas .