中华临床医师杂志(电子版)
中華臨床醫師雜誌(電子版)
중화림상의사잡지(전자판)
CHINESE JOURNAL OF CLINICIANS(ELECTRONIC VERSION)
2013年
5期
2038-2041
,共4页
李婷%李剑明%史蓉芳%陈越%卢如明%梁钰
李婷%李劍明%史蓉芳%陳越%盧如明%樑鈺
리정%리검명%사용방%진월%로여명%량옥
心肌梗死%放射性核素显像%疾病模型,动物%经皮冠状动脉
心肌梗死%放射性覈素顯像%疾病模型,動物%經皮冠狀動脈
심기경사%방사성핵소현상%질병모형,동물%경피관상동맥
Myocardial infarction%Radionuclide imaging%Disease models,animal%Percutaneous coronary artery
目的应用SPECT心肌灌注显像(MPI)对介入栓塞法猪急性心肌梗死(AMI)模型进行评价,总结获得最佳图像质量的显像条件,为相关实验研究提供借鉴。方法采用经冠状动脉丝线堵塞法制作小型猪AMI模型18头,于模型制作后1周行MPI。观察显像剂不同剂量、注射后不同显像间隔时间、采集方式及每帧采集时间对图像质量的影响;同时应用ECToolBox软件进行图像半定量分析。结果(1)注射低剂量显像剂,采用注射至采集间隔30 min+门控采集30 s/帧与间隔时间≥60 min+门控采集25 s或30 s/帧图像无统计学差别;(2)注射高剂量显像剂,注射至采集间隔时间5~10 min+门控采集25 s/帧,与低剂量组间隔≥30 min+门控采集30 s/帧图像无统计学差别。(3)应用半定量分析软件ECToolBox能够同时获得心肌梗死面积、舒张末期容积(EDV)、收缩末期容积(ESV)、左心室射血分数(LVEF)等定量参数,且可重复性好。结论 SPECT MPI能够无创性、直观评价猪AMI模型成功与否,并同时能半定量分析多项参数,结果重复性好;应用适宜的显像条件和操作方法能够有效地提高图像质量。
目的應用SPECT心肌灌註顯像(MPI)對介入栓塞法豬急性心肌梗死(AMI)模型進行評價,總結穫得最佳圖像質量的顯像條件,為相關實驗研究提供藉鑒。方法採用經冠狀動脈絲線堵塞法製作小型豬AMI模型18頭,于模型製作後1週行MPI。觀察顯像劑不同劑量、註射後不同顯像間隔時間、採集方式及每幀採集時間對圖像質量的影響;同時應用ECToolBox軟件進行圖像半定量分析。結果(1)註射低劑量顯像劑,採用註射至採集間隔30 min+門控採集30 s/幀與間隔時間≥60 min+門控採集25 s或30 s/幀圖像無統計學差彆;(2)註射高劑量顯像劑,註射至採集間隔時間5~10 min+門控採集25 s/幀,與低劑量組間隔≥30 min+門控採集30 s/幀圖像無統計學差彆。(3)應用半定量分析軟件ECToolBox能夠同時穫得心肌梗死麵積、舒張末期容積(EDV)、收縮末期容積(ESV)、左心室射血分數(LVEF)等定量參數,且可重複性好。結論 SPECT MPI能夠無創性、直觀評價豬AMI模型成功與否,併同時能半定量分析多項參數,結果重複性好;應用適宜的顯像條件和操作方法能夠有效地提高圖像質量。
목적응용SPECT심기관주현상(MPI)대개입전새법저급성심기경사(AMI)모형진행평개,총결획득최가도상질량적현상조건,위상관실험연구제공차감。방법채용경관상동맥사선도새법제작소형저AMI모형18두,우모형제작후1주행MPI。관찰현상제불동제량、주사후불동현상간격시간、채집방식급매정채집시간대도상질량적영향;동시응용ECToolBox연건진행도상반정량분석。결과(1)주사저제량현상제,채용주사지채집간격30 min+문공채집30 s/정여간격시간≥60 min+문공채집25 s혹30 s/정도상무통계학차별;(2)주사고제량현상제,주사지채집간격시간5~10 min+문공채집25 s/정,여저제량조간격≥30 min+문공채집30 s/정도상무통계학차별。(3)응용반정량분석연건ECToolBox능구동시획득심기경사면적、서장말기용적(EDV)、수축말기용적(ESV)、좌심실사혈분수(LVEF)등정량삼수,차가중복성호。결론 SPECT MPI능구무창성、직관평개저AMI모형성공여부,병동시능반정량분석다항삼수,결과중복성호;응용괄의적현상조건화조작방법능구유효지제고도상질량。
Objective To assess acute myocardial infarction ( AMI) models with the intervention embolism method in minipigs by SPECT myocardial perfusion imaging ( MPI ) .Methods The middle-far segments of left descending coronary arteries in eighteen minipigs were obstructed with thread by percutaneous intervention method to prepare AMI models .SPECT MPI was performed one week after the procedure .Under the changes of the acquisition parameters,the results of influences on image qualities were analyzed by changing of the agent dose ,the interval between the injection and the scan ,the acquisition mode and the time for each projection .Then the data were semi-quantitatively evaluated with ECToolBox software ,acquiring a series of quantificational parameters .Results First, the image quality had no difference between the two acquisition modes after the injection when the imaging agent dose was relatively low.One was the 30 min interval before the adopted ECG gated mode (30 s per frame),and the other one was over 60 min before the adopted ECG gated mode (25 s or 30 s per frame).Second,the time interval only need 5-10 min when the dose was relatively high ,then with the ECG gated acquisition mode ( 25 s per frame ) .The image quality was good enough .There was no difference with the low dose injection ,the time interval of more than 30 min and ECG gated acquisition mode (30 s per frame).Third,it was proved to be highly reproducible using the semi-quantitatively analysis software ( ECToolBox ) , and many quantificational parameters were simultaneously obtained , including the size of myocardial infarction , the weigh of infracted myocardium and the percentage , end diastolic volume(EDV),end systolic volume (ESV) and the LVEF and so on.Conclusions SPECT MPI can be used for intuitively evaluating the success or failure of AMI models in pigs , and actualize quantitative analysis in the same time.The results for semi-quantitatively analysis are highly reproducible .Feasible scan condition and manipulation can effectively improve the image quality .