分析提出的抽头电感单级升压逆变器所有可能的运行状态,揭示在一个直通周期内,除了期望的3种运行状态外,还存在4种对能量传递过程不起作用,甚至给电路运行造成一定危害的运行状态。这4种运行状态可通过合理设计电感和电容值加以避免。从稳态分析中得到描述电路运行的状态方程组,展示能准确设计无源网络的方法,使其运行于期望的直通和非直通状态。提供的方法还可估计电感和电容的极限值,避免电路出现不正常的运行状态。仿真和实验验证了该设计方法的有效性和精确性,同时展示了当电感和电容低于极限值时出现的不正常运行状态。
分析提齣的抽頭電感單級升壓逆變器所有可能的運行狀態,揭示在一箇直通週期內,除瞭期望的3種運行狀態外,還存在4種對能量傳遞過程不起作用,甚至給電路運行造成一定危害的運行狀態。這4種運行狀態可通過閤理設計電感和電容值加以避免。從穩態分析中得到描述電路運行的狀態方程組,展示能準確設計無源網絡的方法,使其運行于期望的直通和非直通狀態。提供的方法還可估計電感和電容的極限值,避免電路齣現不正常的運行狀態。倣真和實驗驗證瞭該設計方法的有效性和精確性,同時展示瞭噹電感和電容低于極限值時齣現的不正常運行狀態。
분석제출적추두전감단급승압역변기소유가능적운행상태,게시재일개직통주기내,제료기망적3충운행상태외,환존재4충대능량전체과정불기작용,심지급전로운행조성일정위해적운행상태。저4충운행상태가통과합리설계전감화전용치가이피면。종은태분석중득도묘술전로운행적상태방정조,전시능준학설계무원망락적방법,사기운행우기망적직통화비직통상태。제공적방법환가고계전감화전용적겁한치,피면전로출현불정상적운행상태。방진화실험험증료해설계방법적유효성화정학성,동시전시료당전감화전용저우겁한치시출현적불정상운행상태。
This paper presents all the possible steady states of the tapped-inductor single-stage boost inverter proposed. It is shown that, in addition to the desired three steady states, an operating cycle can contain another four abnormal states that do not contribute to the power conversion process. These four states can be avoided by selecting suitable value of the capacitors and inductors. By using the equations derived from the steady-state analysis, this paper also presents guidelines to design the impedance network accurately for the case when the inverter is operated only in the desired active and shoot-through states. The proposed design method can also be used to estimate the critical values of capacitance and inductance, in order to avoid those four states appearing during the operating cycle. Experiments are used to verify the design method and to demonstrate the appearance of the four states when the capacitors and inductors are smaller than their critical values.