中国化学工程学报(英文版)
中國化學工程學報(英文版)
중국화학공정학보(영문판)
CHINESE JOURNAL OF CHEMICAL ENGINEERING
2013年
8期
914-919
,共6页
pH%carbon filter%activated carbon%surface functional groups%modification
An investigation was carried out to eliminate the decrease of effluent pH value in carbon filter in O3-biological activated carbon process. The influence factors were examined in a pilot test, and pH was adjusted in the pilot and waterworks. Results show that the carbon filter is an acid-base buffer system and the activated carbon is the key factor. Chemical functional groups on activated carbon surface present acid-base properties to buffer the water but decrease with time, so that effluent pH value decreases. The effects of ozone dosage, CO2 in the carbon filter, and the filter influent quality are negligible. A new method to adjust pH is developed:the activated carbon is first modified by soaking in sodium hydroxide solution to make its pH reach the desired value, and then the pH value of inflow is controlled to certain value by dosing lime in sand filter influent. The method is economical and effective.