3.0T磁共振成像%扩散张量成像%骨髓型颈椎病%各向异性值%表观扩散系数
3.0T磁共振成像%擴散張量成像%骨髓型頸椎病%各嚮異性值%錶觀擴散繫數
3.0T자공진성상%확산장량성상%골수형경추병%각향이성치%표관확산계수
3.0T magnetic resonance scanner%diffusion tensor imaging%cervical spondylotic myelopathy%fractional anisotropy values%apparent diffusion coefifcient values
目的探讨3.0T磁共振(MR)扩散张量成像(DTI)在脊髓型颈椎病早期诊断中的应用价值。方法选择20例健康志愿者作为对照组和80例T2WI无高信号的颈髓型颈椎病患者行颈髓常规磁共振成像(MRI)和DTI扫描,根据患者有无椎管狭窄将其分为椎管无狭窄组(A组,43例)和椎管狭窄组(B组,37例)。分析各组颈髓分数各向异性(FA)值和表观扩散系数(ADC)值的变化。结果对照组颈髓平均FA值为0.643±0.051,ADC值为(1.161±0.172)×10-3 mm2/s;A组和B组患者颈髓平均FA值分别为0.621±0.036、0.592±0.060;平均ADC值分别为(1.236±0.135)×10-3 mm2/s、(1.429±0.150)×10-3 mm2/s。三组之间两两比较,FA值对照组最高,A组次之,B组最低(P值均<0.05);ADC值对照组最低,A组次之,B组最高(P值均<0.05)。结论颈髓DTI成像较常规T2WI更早显示脊髓型颈椎病患者的颈髓损伤,椎管狭窄患者颈髓损伤程度更重。
目的探討3.0T磁共振(MR)擴散張量成像(DTI)在脊髓型頸椎病早期診斷中的應用價值。方法選擇20例健康誌願者作為對照組和80例T2WI無高信號的頸髓型頸椎病患者行頸髓常規磁共振成像(MRI)和DTI掃描,根據患者有無椎管狹窄將其分為椎管無狹窄組(A組,43例)和椎管狹窄組(B組,37例)。分析各組頸髓分數各嚮異性(FA)值和錶觀擴散繫數(ADC)值的變化。結果對照組頸髓平均FA值為0.643±0.051,ADC值為(1.161±0.172)×10-3 mm2/s;A組和B組患者頸髓平均FA值分彆為0.621±0.036、0.592±0.060;平均ADC值分彆為(1.236±0.135)×10-3 mm2/s、(1.429±0.150)×10-3 mm2/s。三組之間兩兩比較,FA值對照組最高,A組次之,B組最低(P值均<0.05);ADC值對照組最低,A組次之,B組最高(P值均<0.05)。結論頸髓DTI成像較常規T2WI更早顯示脊髓型頸椎病患者的頸髓損傷,椎管狹窄患者頸髓損傷程度更重。
목적탐토3.0T자공진(MR)확산장량성상(DTI)재척수형경추병조기진단중적응용개치。방법선택20례건강지원자작위대조조화80례T2WI무고신호적경수형경추병환자행경수상규자공진성상(MRI)화DTI소묘,근거환자유무추관협착장기분위추관무협착조(A조,43례)화추관협착조(B조,37례)。분석각조경수분수각향이성(FA)치화표관확산계수(ADC)치적변화。결과대조조경수평균FA치위0.643±0.051,ADC치위(1.161±0.172)×10-3 mm2/s;A조화B조환자경수평균FA치분별위0.621±0.036、0.592±0.060;평균ADC치분별위(1.236±0.135)×10-3 mm2/s、(1.429±0.150)×10-3 mm2/s。삼조지간량량비교,FA치대조조최고,A조차지,B조최저(P치균<0.05);ADC치대조조최저,A조차지,B조최고(P치균<0.05)。결론경수DTI성상교상규T2WI경조현시척수형경추병환자적경수손상,추관협착환자경수손상정도경중。
Objective To evaluate the effects of DTI (Diffusion Tensor Imaging) in patients with CSM (Cervical Spondylotic Myelopathy). Methods Conventional MRI (Magnetic Resonance Imaging) and DTI were performed in 20 healthy volunteers who were selected as the Control group. While, 80 CSM sufferers without high signals to T2WI (T2-weighted Imaging) were scanned with conventional MRI and DTI by a 3.0T MR scanner and divided into two groups (group A:43 cases of patients without spinal stenoses; group B: 37 cases of patients with spinal stenoses) according to their scanning results. Then, analysis of the changes in FA (Fractional Anisotropy) and ADC (Apparent Diffusion Coefifcient) values were performed. Results The average FA and ADC values of the Control group were 0.643±0.051 and (1.161±0.172)×10-3mm2/s respectively. The FA values of group A and B were 0.621±0.036 and 0.592±0.060 respectively; the ADC values of group A and B were ( 1.236±0.135)×10-3mm2/s and (1.429±0.150)×10-3mm2/s respectively. On mean FA values, the Control Group ranked the ifrst while Group B the third ( p<0.05). As for the mean ADC values, group B was the highest ( p<0.05) while the Control group was the lowest. Conclusion In comparison with conventional T2WI, DTI allowed earlier manifestation of the spondylosis-related changes in CSM patients.