预应力锚索%张拉异常情况%分析及处理
預應力錨索%張拉異常情況%分析及處理
예응력묘색%장랍이상정황%분석급처리
prestressed anchor cable%tensile abnormal%analysis and processing
针对锦屏一级水电站水垫塘右岸倒悬体预应力锚索张拉施工中出现的问题,介绍了锚索张拉的异常情况,对锚索张拉异常情况进行了分析,提出了处理措施,工程实践效果良好,可供借鉴。
針對錦屏一級水電站水墊塘右岸倒懸體預應力錨索張拉施工中齣現的問題,介紹瞭錨索張拉的異常情況,對錨索張拉異常情況進行瞭分析,提齣瞭處理措施,工程實踐效果良好,可供藉鑒。
침대금병일급수전참수점당우안도현체예응력묘색장랍시공중출현적문제,개소료묘색장랍적이상정황,대묘색장랍이상정황진행료분석,제출료처리조시,공정실천효과량호,가공차감。
In order to solve the problem of prestressed anchor cable tensile construction of the right bank overhanging structure of water cushion pool of Jinping Hydropower Station , the abnormal cable tension are introduced and analyzed . Treatment measures are put forward , which proves good effect in engineering practice and provides reference for similar problems.