头孢唑啉钠%抗生素废水%内电解
頭孢唑啉鈉%抗生素廢水%內電解
두포서람납%항생소폐수%내전해
以头孢唑啉钠模拟抗生素废水作为处理对象,对内电解法进行了强化技术的研究.实验结果表明,当氯化铜、硝酸镍、硫酸锰、双氧水的投加量分别为0.136,0.549,0.338 g/L,15 mL/L时,头孢唑啉钠和COD的去除率分别为30.98%和29.9%,33.4%和33.5%,30.6%和34.1%,41.5%和60.0%.投加氯化铜、硝酸镍、硫酸锰、双氧水等催化剂强化后,可生化性均得到进一步提高,分别为0.469,0.497,0.437,0.582.
以頭孢唑啉鈉模擬抗生素廢水作為處理對象,對內電解法進行瞭彊化技術的研究.實驗結果錶明,噹氯化銅、硝痠鎳、硫痠錳、雙氧水的投加量分彆為0.136,0.549,0.338 g/L,15 mL/L時,頭孢唑啉鈉和COD的去除率分彆為30.98%和29.9%,33.4%和33.5%,30.6%和34.1%,41.5%和60.0%.投加氯化銅、硝痠鎳、硫痠錳、雙氧水等催化劑彊化後,可生化性均得到進一步提高,分彆為0.469,0.497,0.437,0.582.
이두포서람납모의항생소폐수작위처리대상,대내전해법진행료강화기술적연구.실험결과표명,당록화동、초산얼、류산맹、쌍양수적투가량분별위0.136,0.549,0.338 g/L,15 mL/L시,두포서람납화COD적거제솔분별위30.98%화29.9%,33.4%화33.5%,30.6%화34.1%,41.5%화60.0%.투가록화동、초산얼、류산맹、쌍양수등최화제강화후,가생화성균득도진일보제고,분별위0.469,0.497,0.437,0.582.