用大量测试数据表明:50%液碱的质量分数检测结果受温度、样品质量以及称量误差等因素的影响。当温度为15~40℃时,温度对其浓度影响较小;但当50%液碱结晶时,对第二方实验室来说,结晶部分不易检测,晶体越多,液态部分的碱浓度越低,50%液碱浓度的变化越大。
用大量測試數據錶明:50%液堿的質量分數檢測結果受溫度、樣品質量以及稱量誤差等因素的影響。噹溫度為15~40℃時,溫度對其濃度影響較小;但噹50%液堿結晶時,對第二方實驗室來說,結晶部分不易檢測,晶體越多,液態部分的堿濃度越低,50%液堿濃度的變化越大。
용대량측시수거표명:50%액감적질량분수검측결과수온도、양품질량이급칭량오차등인소적영향。당온도위15~40℃시,온도대기농도영향교소;단당50%액감결정시,대제이방실험실래설,결정부분불역검측,정체월다,액태부분적감농도월저,50%액감농도적변화월대。
The following conclusions were drawn from a large amount of test data .The mass fraction test results of 50 wt% caustic soda solution were influenced by temperature , unstable sample quality , weighing error , etc.The test results of 50 wt% caustic soda solution were less influenced by the temperature when the temperature ranged from 10 to 40 ℃.When the 50 wt% caustic soda solution crystallized , the part of crystal was not easy to test in the second party laboratory .The more the crystal , the lower the caustic soda concentration of the liquid part , and the larger the change of concentration of 50 wt%caustic soda solution .