电力系统保护与控制
電力繫統保護與控製
전력계통보호여공제
POWER SYSTM PROTECTION AND CONTROL
2013年
20期
67-74
,共8页
杨艺云%司传涛%廖波%周林
楊藝雲%司傳濤%廖波%週林
양예운%사전도%료파%주림
光伏并网功率调节系统%正序基波提取器%谐波检测%K参数%指令电流合成
光伏併網功率調節繫統%正序基波提取器%諧波檢測%K參數%指令電流閤成
광복병망공솔조절계통%정서기파제취기%해파검측%K삼수%지령전류합성
grid-connected photovoltaic power conditioning system%positive sequence fundamental wave extractor%harmonic detecting%parameter K%directive current composing
光伏并网功率调节系统实现光伏并网与有源滤波的统一控制,关键是谐波、无功电流的准确检测和并网指令电流的形成。考虑实际电网电压有畸变或频率偏差,为获得准确谐波、无功电流和同步正弦,利用幅值积分及其频率选择特性构成正序基波提取器,深入分析正序基波提取器中K参数设计方法,推导出K值的计算表达式,合理取K值,可准确提取正序基波,无需锁相环可得到同步正、余弦信号。分析了谐波、无功及不对称分量之和的检测方法和并网指令电流的合成方式,实现光伏有功注入与谐波抑制、无功补偿功能。最后进行Matlab/Simulink仿真,仿真结果验证了理论分析的正确性。针对K参数对正序基波提取的影响,完成了其小功率实验,实验结果进一步证明该方法的正确性。
光伏併網功率調節繫統實現光伏併網與有源濾波的統一控製,關鍵是諧波、無功電流的準確檢測和併網指令電流的形成。攷慮實際電網電壓有畸變或頻率偏差,為穫得準確諧波、無功電流和同步正絃,利用幅值積分及其頻率選擇特性構成正序基波提取器,深入分析正序基波提取器中K參數設計方法,推導齣K值的計算錶達式,閤理取K值,可準確提取正序基波,無需鎖相環可得到同步正、餘絃信號。分析瞭諧波、無功及不對稱分量之和的檢測方法和併網指令電流的閤成方式,實現光伏有功註入與諧波抑製、無功補償功能。最後進行Matlab/Simulink倣真,倣真結果驗證瞭理論分析的正確性。針對K參數對正序基波提取的影響,完成瞭其小功率實驗,實驗結果進一步證明該方法的正確性。
광복병망공솔조절계통실현광복병망여유원려파적통일공제,관건시해파、무공전류적준학검측화병망지령전류적형성。고필실제전망전압유기변혹빈솔편차,위획득준학해파、무공전류화동보정현,이용폭치적분급기빈솔선택특성구성정서기파제취기,심입분석정서기파제취기중K삼수설계방법,추도출K치적계산표체식,합리취K치,가준학제취정서기파,무수쇄상배가득도동보정、여현신호。분석료해파、무공급불대칭분량지화적검측방법화병망지령전류적합성방식,실현광복유공주입여해파억제、무공보상공능。최후진행Matlab/Simulink방진,방진결과험증료이론분석적정학성。침대K삼수대정서기파제취적영향,완성료기소공솔실험,실험결과진일보증명해방법적정학성。
The key for PV grid-connected power conditioning system to realize the uniform control of PV grid-connected and active filter is to correctly detect harmonic and reactive current and form grid-connected directive current. Considering distortion and frequency deviation of the actual grid voltage, to get the correct harmonic, reactive current and synchronous sine, the amplitude integral and selective characteristic of frequency are used to form the positive sequence fundamental extractor. The K in the positive sequence fundamental extractor is further analyzed, and then the operation expression of K is derived. If K is chosen properly, positive-sequence fundamental can be got correctly, and synchronous sine and cosine can be got without the phase lock loop. The detecting method for the harmonic, reactive power, and the sum of unsymmetrical components, as well as the grid-connected directive current composing method is analyzed to realize the active power injection, harmonic eliminating and reactive power compensation. The simulation in Matlab/Simulink verifies the correctness of the theoretical analysis. For the effect of K on the positive-sequence fundamental extracting, the miniwatt experiment is conducted to further verify the correctness of the method.