架空地线与导线之间存在电磁感应,由此带来架空地线电能损耗问题。对架空地线节能接地技术进行系统研究,提出架空地线感应电压的控制原则,区分单回、多回线路提出架空地线节能接地方式以及地线分段节距计算公式。提出地线绝缘子及间隙选型要求,给出标准大气压以及不同海拔、温度、湿度条件下间隙距离参数,对冰区绝缘子还提出了覆冰绝缘配置和直流融冰技术要求。提出多种光纤复合地线(optical fiber composite overhead ground wire, OPGW)节能接续方案,并介绍了OPGW常用金具。提出的架空地线节能接地技术已在广东电网冰区、非冰区线路中实际应用。
架空地線與導線之間存在電磁感應,由此帶來架空地線電能損耗問題。對架空地線節能接地技術進行繫統研究,提齣架空地線感應電壓的控製原則,區分單迴、多迴線路提齣架空地線節能接地方式以及地線分段節距計算公式。提齣地線絕緣子及間隙選型要求,給齣標準大氣壓以及不同海拔、溫度、濕度條件下間隙距離參數,對冰區絕緣子還提齣瞭覆冰絕緣配置和直流融冰技術要求。提齣多種光纖複閤地線(optical fiber composite overhead ground wire, OPGW)節能接續方案,併介紹瞭OPGW常用金具。提齣的架空地線節能接地技術已在廣東電網冰區、非冰區線路中實際應用。
가공지선여도선지간존재전자감응,유차대래가공지선전능손모문제。대가공지선절능접지기술진행계통연구,제출가공지선감응전압적공제원칙,구분단회、다회선로제출가공지선절능접지방식이급지선분단절거계산공식。제출지선절연자급간극선형요구,급출표준대기압이급불동해발、온도、습도조건하간극거리삼수,대빙구절연자환제출료복빙절연배치화직류융빙기술요구。제출다충광섬복합지선(optical fiber composite overhead ground wire, OPGW)절능접속방안,병개소료OPGW상용금구。제출적가공지선절능접지기술이재엄동전망빙구、비빙구선로중실제응용。
Becaused of the electromagnetic induction between overhead ground wires and conductors,there is a huge power loss of overhead ground wires.Systematic study was carried out on the energy-saving grounding technology for overhead ground wires.The control principle of induced voltage of overhead ground wires was proposed,and different energy-saving grounding modes and calculation formula of segmented distance for overhead ground wires were presented according to single-circuit or double-circuit.Then,this paper proposed the selection requirements of ground wire insulator and its parallel gaps,and also introduced in detail how to choose the gap distance under standard atmospheric pressure,as well as different altitude,temperature and humidity conditions.For ground wire insulators in the icing area,this paper also proposed technical requirements of insulation configuration and DC ice melting.Finally,this paper suggested a variety of energy-saving splicing schemes of OPGW,and also introduced the common OPGW fittings.The proposed energy-saving grounding technology of overhead ground wires has been applied in Guangdong Power Grid,including overhead transmission lines in icing zone and non-icing zone.