目的:探讨多层螺旋CT对气道异物的诊断价值。方法对门诊收治疑似气管异物患者56例,给予多层螺旋CT检查,并与支气管镜检查作对照。结果多层螺旋CT检查共检出气道异物患者52例,1例误诊为肺炎,后经气管镜检查并取出异物,漏诊2例,假阳性1例。多层螺旋CT检查及气管镜对气道异物检出率差异无统计学意义(χ2=0.61, P >0.05)。以支气管镜检查结果为金标准,螺旋 CT 灵敏度为96.23%,特异度为66.67%,诊断符合率为94.64%。结论多层螺旋CT检查气道异物,具有灵敏度高、符合率高特点,诊断时应结合病史、临床体征,以降低误诊率、漏诊率。儿童检查应以最低剂量扫描,避免辐射损伤。
目的:探討多層螺鏇CT對氣道異物的診斷價值。方法對門診收治疑似氣管異物患者56例,給予多層螺鏇CT檢查,併與支氣管鏡檢查作對照。結果多層螺鏇CT檢查共檢齣氣道異物患者52例,1例誤診為肺炎,後經氣管鏡檢查併取齣異物,漏診2例,假暘性1例。多層螺鏇CT檢查及氣管鏡對氣道異物檢齣率差異無統計學意義(χ2=0.61, P >0.05)。以支氣管鏡檢查結果為金標準,螺鏇 CT 靈敏度為96.23%,特異度為66.67%,診斷符閤率為94.64%。結論多層螺鏇CT檢查氣道異物,具有靈敏度高、符閤率高特點,診斷時應結閤病史、臨床體徵,以降低誤診率、漏診率。兒童檢查應以最低劑量掃描,避免輻射損傷。
목적:탐토다층라선CT대기도이물적진단개치。방법대문진수치의사기관이물환자56례,급여다층라선CT검사,병여지기관경검사작대조。결과다층라선CT검사공검출기도이물환자52례,1례오진위폐염,후경기관경검사병취출이물,루진2례,가양성1례。다층라선CT검사급기관경대기도이물검출솔차이무통계학의의(χ2=0.61, P >0.05)。이지기관경검사결과위금표준,라선 CT 령민도위96.23%,특이도위66.67%,진단부합솔위94.64%。결론다층라선CT검사기도이물,구유령민도고、부합솔고특점,진단시응결합병사、림상체정,이강저오진솔、루진솔。인동검사응이최저제량소묘,피면복사손상。
Objective To investigate the value of multislice CT in the diagnosis of airway foreign bodies . Methods Fifty-six patients with suspected airway foreign body were given multislice CT examination , and their ex-amined results were contrastod with the results obtained by bronchoscopy .Results Multislice CT examination detec-ted airway foreign body in 52 patients, 1 case was misdiagnosed as pneumonia , and the foreign body was removed by bronchoscope examination;Between multislice CT and bronchoscope there was no statistically difference in foreign body detection rate (χ2 =0.61 , P>0.05 ); With bronchoscope examination results as the gold standard , spiral CT sensitivity was 96.23%, the diagnostic coincidence rate was 96.64%.Conclusion Multislice CT examination for airway foreign bodies have the characteristics of high sensitivity , high coincidence rate , but also should be combined with the history, clinical signs, in order to reduce the incidence of misdiagnosis , missed diagnosis.For children, multislice CT examination should be penformed at the lowest dose scanning , in order to avoid radiation damage .