리의%양랑%담춘강%라위
循环水系统%水泵%节电
循環水繫統%水泵%節電
순배수계통%수빙%절전
circulating cooling water system%pumps in parallel%electricity saving
以并联水泵供水的循环冷却水系统为节电对象,分步实施了水泵叶轮切削,单台水泵变频调速的组合控制方案,优化了水泵的工作点,实现了自动调节的恒压供水,完全消除了泵后闸阀的节流损失,总体节电率达46.8%。
以併聯水泵供水的循環冷卻水繫統為節電對象,分步實施瞭水泵葉輪切削,單檯水泵變頻調速的組閤控製方案,優化瞭水泵的工作點,實現瞭自動調節的恆壓供水,完全消除瞭泵後閘閥的節流損失,總體節電率達46.8%。
이병련수빙공수적순배냉각수계통위절전대상,분보실시료수빙협륜절삭,단태수빙변빈조속적조합공제방안,우화료수빙적공작점,실현료자동조절적항압공수,완전소제료빙후갑벌적절류손실,총체절전솔체46.8%。
This paper studied the circulating cooling water system with pumps in parallel for saving e-lectricity,and introduced implementation of combination plan of pump impeller trimming plus a single pump′s VFD.The system has achieved optimization with pump working point and automatic constant control with water supply pressure,completely eliminating pump valve throttling losses and realizing a remarkable power saving as high as 46.8%.