目的:探讨采用低剂量扫描条件和低剂量对比剂进行128层螺旋CT头颈部动脉造影的可行性。方法将100例接受头颈部CT血管造影(CTA)检查的患者随机分为研究组和对照组,管电压、管电流和对比剂用量分别为100 kV、300 mA、50 ml和120 kV、450 mA、70 ml,对比分析图像质量、血管强化情况、静脉硬化伪影及辐射剂量、对比剂剂量。结果①除右侧锁骨下动脉外,各主要动脉节段影像评分两组间差异无统计学意义(P>0.05);②研究组CT值高于对照组(P<0.05);③对照组静脉伪影较研究组明显(P<0.05)。④对照组辐射剂量及对比剂用量明显高于研究组(P<0.05)。结论采用低剂量扫描条件和低剂量对比剂进行头颈部128层螺旋CTA可获得较好的图像质量。
目的:探討採用低劑量掃描條件和低劑量對比劑進行128層螺鏇CT頭頸部動脈造影的可行性。方法將100例接受頭頸部CT血管造影(CTA)檢查的患者隨機分為研究組和對照組,管電壓、管電流和對比劑用量分彆為100 kV、300 mA、50 ml和120 kV、450 mA、70 ml,對比分析圖像質量、血管彊化情況、靜脈硬化偽影及輻射劑量、對比劑劑量。結果①除右側鎖骨下動脈外,各主要動脈節段影像評分兩組間差異無統計學意義(P>0.05);②研究組CT值高于對照組(P<0.05);③對照組靜脈偽影較研究組明顯(P<0.05)。④對照組輻射劑量及對比劑用量明顯高于研究組(P<0.05)。結論採用低劑量掃描條件和低劑量對比劑進行頭頸部128層螺鏇CTA可穫得較好的圖像質量。
목적:탐토채용저제량소묘조건화저제량대비제진행128층라선CT두경부동맥조영적가행성。방법장100례접수두경부CT혈관조영(CTA)검사적환자수궤분위연구조화대조조,관전압、관전류화대비제용량분별위100 kV、300 mA、50 ml화120 kV、450 mA、70 ml,대비분석도상질량、혈관강화정황、정맥경화위영급복사제량、대비제제량。결과①제우측쇄골하동맥외,각주요동맥절단영상평분량조간차이무통계학의의(P>0.05);②연구조CT치고우대조조(P<0.05);③대조조정맥위영교연구조명현(P<0.05)。④대조조복사제량급대비제용량명현고우연구조(P<0.05)。결론채용저제량소묘조건화저제량대비제진행두경부128층라선CTA가획득교호적도상질량。
Objective To evaluate the feasibility of low-dose radiation and low volume contrast medium pro-tocol for cerebral and carotid CTA with 128-slice spiral CT scanner.Methods Totally 100 patients who underwent cere-bral and carotid CTA were included and divided randomly into experimental group and control group,with the tube voltage of 100kVand 120kV,tube current of 300mA and 450mA,and contrast medium of 50mland 70ml,respectively. Image quality,vascular enhancement,venous artifacts as well as the radiation dose were independently compared be-tween the two groups.Results ①There was no significant difference of image quality of the cerebral and carotid ar-teries except for the right subclavian artery between the two groups(P>0.05).②The CT number in experimental group was higher than that in control group (P<0.05).③The grading score of venous artifacts in control group was significantly higher than that in experimental group (P<0.05).④The radiation dose and the contrast medium vol-ume in experimental group was significantly lower than that in control group(P<0.05).Conclusion The applica-tion of 128-slice CT scanner withlow-dose radiation and low volume contrast medium protocol for cerebral and carotid CTA can result in high quality images.