中华临床医师杂志(电子版)
中華臨床醫師雜誌(電子版)
중화림상의사잡지(전자판)
CHINESE JOURNAL OF CLINICIANS(ELECTRONIC VERSION)
2013年
19期
8627-8631
,共5页
方红丽%谭佳%许雪亮%杨婧
方紅麗%譚佳%許雪亮%楊婧
방홍려%담가%허설량%양청
眶骨折%眼球内陷%复视%多孔高密度聚乙烯%Medpor
眶骨摺%眼毬內陷%複視%多孔高密度聚乙烯%Medpor
광골절%안구내함%복시%다공고밀도취을희%Medpor
Orbital blowout fractures%Enophthalmos%Diplopia%Porous high-density polyethylene%Medpor
目的:研究人体整形的新型高分子材料-Medpor(多孔高密度聚乙烯)整复眼眶爆裂性骨折的临床效果及其特点。方法对31例患者均行高分辨率眼眶CT扫描和三维重建、了解眼眶骨折的部位、大小;用Hertel突眼计测量眼球内陷度数;Lancaster红绿灯测量法分析复视情况。以Medpor作为手术整复材料,并进行6~22个月随访。结果术前31例患者随访6个月及以上,其中:26例患者眼球内陷,20例患者眼球内陷完全矫正(76.92%),6例患者好转(23.08%);术前23例伴有复视患者,18例复视完全矫正(78.26%),5例复视好转(21.74%);术前20例患者眼球运动受限,12例恢复正常(60%),8例好转(40%)。结论 Medpor作为近年来用于临床的新型整形材料,具有生物相容性好、术后支撑能力强、稳定性高、易于固定、填充量可选的特点,并可以根据骨折范围、眼球内陷程度对材料进行热处理后修剪成型,用于眼眶骨折的整复,能有效的矫正中重度眼球内陷,复视明显的患者。
目的:研究人體整形的新型高分子材料-Medpor(多孔高密度聚乙烯)整複眼眶爆裂性骨摺的臨床效果及其特點。方法對31例患者均行高分辨率眼眶CT掃描和三維重建、瞭解眼眶骨摺的部位、大小;用Hertel突眼計測量眼毬內陷度數;Lancaster紅綠燈測量法分析複視情況。以Medpor作為手術整複材料,併進行6~22箇月隨訪。結果術前31例患者隨訪6箇月及以上,其中:26例患者眼毬內陷,20例患者眼毬內陷完全矯正(76.92%),6例患者好轉(23.08%);術前23例伴有複視患者,18例複視完全矯正(78.26%),5例複視好轉(21.74%);術前20例患者眼毬運動受限,12例恢複正常(60%),8例好轉(40%)。結論 Medpor作為近年來用于臨床的新型整形材料,具有生物相容性好、術後支撐能力彊、穩定性高、易于固定、填充量可選的特點,併可以根據骨摺範圍、眼毬內陷程度對材料進行熱處理後脩剪成型,用于眼眶骨摺的整複,能有效的矯正中重度眼毬內陷,複視明顯的患者。
목적:연구인체정형적신형고분자재료-Medpor(다공고밀도취을희)정복안광폭렬성골절적림상효과급기특점。방법대31례환자균행고분변솔안광CT소묘화삼유중건、료해안광골절적부위、대소;용Hertel돌안계측량안구내함도수;Lancaster홍록등측량법분석복시정황。이Medpor작위수술정복재료,병진행6~22개월수방。결과술전31례환자수방6개월급이상,기중:26례환자안구내함,20례환자안구내함완전교정(76.92%),6례환자호전(23.08%);술전23례반유복시환자,18례복시완전교정(78.26%),5례복시호전(21.74%);술전20례환자안구운동수한,12례회복정상(60%),8례호전(40%)。결론 Medpor작위근년래용우림상적신형정형재료,구유생물상용성호、술후지탱능력강、은정성고、역우고정、전충량가선적특점,병가이근거골절범위、안구내함정도대재료진행열처리후수전성형,용우안광골절적정복,능유효적교정중중도안구내함,복시명현적환자。
Objective To investigate the clinical results and relative merits of new high-polymer material for body modification-Medpor in the repair of orbital blowout fracture(BOF). Methods To thirty one patients, High resolution CT scan and 3-D reconstruction were used for the lactation and size of BOF;Hertel exophthalmometer was used for the measurement of enophthalmos;Lancaster test was used for examination of diplopia. Medpor as orbital grafting material was used for patients who followed up for six months at least. Results 31 cases had followed up for 6 months at least. Of 31 cases:twenty six had enophthalmos preoperatively, 20 of 26 cases(76.92%) was corrected, and 6 of 26 cases(23.08%)was improved;23 cases had diplopia preoperatively, 18 cases was corrected(78.26%) and 5 cases was improved(21.74%); 20 patients preoperatively had eye movement disorders of BOF, 12 of 20(60%) cases was corrected, and the rest 8 cases(40%) was improved. Conclusions Recently, Medpor as a new high-polymer material for body modification in clinic has many merits, for example:good biocompatibility, strong support capability, high stability, easy to be fixed;filling volume chosen and so on. It can be shaped through heat treatment according to the size of BOF and degree of eyeball enophthalmos and used to repair BOF. Medpor is the preferred repairing materials to patients of BOF with enophthalmos obviously and diplopia.