以中试填料萃取塔为设备研究了复合萃取剂(正辛醇和煤油)萃取林可霉素的宏观特性及传质强化。使用斜率法确定萃合物的结构和反应平衡常数以指导改进设备和强化传质;为了提高林可霉素萃取效果,考察了溶液 pH 值、相比(W/O)、填料类型、分布盘的使用等因素对提取林可霉素效果的影响。结果表明:以正辛醇为萃取剂萃取林可霉素的过程中,反应平衡常数K为0.072;复合萃取剂中正辛醇最佳含量为0.8(体积分数);萃取林可霉素的最佳pH值为10~11,最佳相比(W/O)为3;规整填料和散装填料萃取效果有限,分布盘可以大大加强传质,同时加装分布盘的填料萃取塔的单位体积处理量是混合澄清槽的12.8倍,萃取剂循环量大大减少。研究结果对复合萃取剂的萃取机理和填料萃取塔提取林可霉素的实际应用具有一定指导意义。
以中試填料萃取塔為設備研究瞭複閤萃取劑(正辛醇和煤油)萃取林可黴素的宏觀特性及傳質彊化。使用斜率法確定萃閤物的結構和反應平衡常數以指導改進設備和彊化傳質;為瞭提高林可黴素萃取效果,攷察瞭溶液 pH 值、相比(W/O)、填料類型、分佈盤的使用等因素對提取林可黴素效果的影響。結果錶明:以正辛醇為萃取劑萃取林可黴素的過程中,反應平衡常數K為0.072;複閤萃取劑中正辛醇最佳含量為0.8(體積分數);萃取林可黴素的最佳pH值為10~11,最佳相比(W/O)為3;規整填料和散裝填料萃取效果有限,分佈盤可以大大加彊傳質,同時加裝分佈盤的填料萃取塔的單位體積處理量是混閤澄清槽的12.8倍,萃取劑循環量大大減少。研究結果對複閤萃取劑的萃取機理和填料萃取塔提取林可黴素的實際應用具有一定指導意義。
이중시전료췌취탑위설비연구료복합췌취제(정신순화매유)췌취림가매소적굉관특성급전질강화。사용사솔법학정췌합물적결구화반응평형상수이지도개진설비화강화전질;위료제고림가매소췌취효과,고찰료용액 pH 치、상비(W/O)、전료류형、분포반적사용등인소대제취림가매소효과적영향。결과표명:이정신순위췌취제췌취림가매소적과정중,반응평형상수K위0.072;복합췌취제중정신순최가함량위0.8(체적분수);췌취림가매소적최가pH치위10~11,최가상비(W/O)위3;규정전료화산장전료췌취효과유한,분포반가이대대가강전질,동시가장분포반적전료췌취탑적단위체적처리량시혼합징청조적12.8배,췌취제순배량대대감소。연구결과대복합췌취제적췌취궤리화전료췌취탑제취림가매소적실제응용구유일정지도의의。
The macroscopic property and mass transfer enhancement of extracting Lincomycin with composite extractant (n-octanol and kerosene) in packed extraction column was studied in this paper. The structure of extracted complex and reaction equilibrium constant were determined by the slope method,which could contribute to the improvement of equipment and mass transfer enhancement. In order to improve the extraction efficiency,factors such as pH of the solution,volume ratio of the water phase to the organic phase,packing type,and distribution plates were considered. The results showed that in the extraction process of Lincomycin with n-octanol,the reaction equilibrium constant was 0.072,the optimum content of n-octanol in composite extractant was 0.8 (volume fraction) , the optimum pH of the extraction solution ranged from 10 to 11 , the optimum volume ratio of the water phase to the organic phase was 3. Limited extraction efficiency was found to present in both structured packing and bulk packing extraction column. Distribution plates could significantly enhance the mass transfer in packed extraction column , with a maximum unit volume treatment capacity of 12.8 times compared to the extraction tank,and the circulation volume of extractant could be greatly reduced. The results can be used for guiding practical application of packed extraction column in Lincomycin extraction.