中华胃肠外科杂志
中華胃腸外科雜誌
중화위장외과잡지
CHINESE JOURNAL OF GASTROINTESTINAL SURGERY
2014年
7期
683-686
,共4页
练延帮%曹务腾%朱珊珊%林杨皓%刘得超%王馨华%邱建平%周智洋
練延幫%曹務騰%硃珊珊%林楊皓%劉得超%王馨華%邱建平%週智洋
련연방%조무등%주산산%림양호%류득초%왕형화%구건평%주지양
克罗恩病%诊断%CT小肠造影%自适应进代降剂量技术
剋囉恩病%診斷%CT小腸造影%自適應進代降劑量技術
극라은병%진단%CT소장조영%자괄응진대강제량기술
Crohn disease%Diagnosis%CT enterography%Adaptive iterative dose reduction
目的 评价自适应迭代降剂量(AIDR)技术在克罗恩病CT小肠造影中的应用.方法 回顾性分析2013年1-3月间中山大学附属第六医院收治并经炎性肠病多学科诊疗小组确诊为克罗恩病的26例患者的临床和影像资料,所有病例均采用AIDR技术行CT小肠造影检查.由两名诊断克罗恩病经验丰富的放射科医生分别阅片,计算每例患者所受电离辐射总量,并分析克罗恩病影像学特点.结果 26例患者辐射剂量为5.58~12.90(9.00±2.00) mSv,明显低于常规使用剂量(15 mSv).克罗恩病CT小肠造影检查发现,26例患者中,1例患者处于静止期,另外25例共出现109处节段性肠壁增厚,合并系膜侧淋巴结肿大,同时出现异常强化现象.其中16例发现肠腔狭窄,12例肠壁呈分层样强化,14例出现“梳样征”;8例出现系膜侧脂肪密度增高,7例肠瘘,6例腹腔脓肿,3例肛瘘.结论 低剂量AIDR技术CT小肠造影技术不会损失图像质量,能够有效诊断克罗恩病并明显降低辐射剂量.
目的 評價自適應迭代降劑量(AIDR)技術在剋囉恩病CT小腸造影中的應用.方法 迴顧性分析2013年1-3月間中山大學附屬第六醫院收治併經炎性腸病多學科診療小組確診為剋囉恩病的26例患者的臨床和影像資料,所有病例均採用AIDR技術行CT小腸造影檢查.由兩名診斷剋囉恩病經驗豐富的放射科醫生分彆閱片,計算每例患者所受電離輻射總量,併分析剋囉恩病影像學特點.結果 26例患者輻射劑量為5.58~12.90(9.00±2.00) mSv,明顯低于常規使用劑量(15 mSv).剋囉恩病CT小腸造影檢查髮現,26例患者中,1例患者處于靜止期,另外25例共齣現109處節段性腸壁增厚,閤併繫膜側淋巴結腫大,同時齣現異常彊化現象.其中16例髮現腸腔狹窄,12例腸壁呈分層樣彊化,14例齣現“梳樣徵”;8例齣現繫膜側脂肪密度增高,7例腸瘺,6例腹腔膿腫,3例肛瘺.結論 低劑量AIDR技術CT小腸造影技術不會損失圖像質量,能夠有效診斷剋囉恩病併明顯降低輻射劑量.
목적 평개자괄응질대강제량(AIDR)기술재극라은병CT소장조영중적응용.방법 회고성분석2013년1-3월간중산대학부속제륙의원수치병경염성장병다학과진료소조학진위극라은병적26례환자적림상화영상자료,소유병례균채용AIDR기술행CT소장조영검사.유량명진단극라은병경험봉부적방사과의생분별열편,계산매례환자소수전리복사총량,병분석극라은병영상학특점.결과 26례환자복사제량위5.58~12.90(9.00±2.00) mSv,명현저우상규사용제량(15 mSv).극라은병CT소장조영검사발현,26례환자중,1례환자처우정지기,령외25례공출현109처절단성장벽증후,합병계막측림파결종대,동시출현이상강화현상.기중16례발현장강협착,12례장벽정분층양강화,14례출현“소양정”;8례출현계막측지방밀도증고,7례장루,6례복강농종,3례항루.결론 저제량AIDR기술CT소장조영기술불회손실도상질량,능구유효진단극라은병병명현강저복사제량.
Objective To evaluate the application of low-dose CT enterography with adaptive iterative dose reduction (AIDR) technique in diagnosing Crohn's disease Methods Retrospective analysis was performed on 26 patients diagnosed as Crohn's disease by the multidisciplinary team in our hospital.Low-dose CT enterography with 640-slice MDCT was performed on these 26 patients using adaptive iterative dose reduction (AIDR) technique.Characteristics of Crohn's disease in CT enterography images were independently analyzed by two radiologists who were experienced in Crohn' s disease with calculating the total radiation dosage.Results The radiation dosage of 26 patients ranged from 5.58 to 12.90 [mean(9.00±2.00)] mSv,which was lower than conventional scan (around 15 mSv) known from the literatures.According to the images of CT enterography of 26 cases,bowel wall thickening with abnormal enhancement and lymphadenectasis were found in 25 cases with total 109 segmental bowel wall thickening.Among 25 thickening cases,enterostenosis was found in 16 cases,stratification enhancement in 12 cases and comb sign in 14 cases.Besides,it was found that 8 cases with hyperdense fat on the mesenteric side,7 cases with intestinal fistula,6 cases with abdominal cavity abscess,and 3 cases with anal fistula.Conclusion CT enterography of Crohn's disease with adaptive iterative dose reduction technique is an effective method to evaluate Crohn' s disease without compromising image quality with reduced radiation dosage.