本文介绍了某发电厂2×600MW机组电除尘内部结焦情况,并就三、四、五电场除尘内部结焦原因进行了分析,提出了预防电除尘内部结焦的技术措施,解决了输灰管线不畅和电除尘内部结焦严重被迫停炉的问题。
本文介紹瞭某髮電廠2×600MW機組電除塵內部結焦情況,併就三、四、五電場除塵內部結焦原因進行瞭分析,提齣瞭預防電除塵內部結焦的技術措施,解決瞭輸灰管線不暢和電除塵內部結焦嚴重被迫停爐的問題。
본문개소료모발전엄2×600MW궤조전제진내부결초정황,병취삼、사、오전장제진내부결초원인진행료분석,제출료예방전제진내부결초적기술조시,해결료수회관선불창화전제진내부결초엄중피박정로적문제。
This article describes the internal coking situation of the Datang International Power Co-Ltd's 2í600MW units' electrostatic precipitator (ESP) and analyzes the reasons on internal coking of the third, fourth and fifth electric field. At the same time, in this paper, some technical measures are proposed what make to prevent coking within the ESP. In addition, the paper solves the problem of ash transporting pipeline jamming and serious coking within ESP which can cause the blowing-out.