实验流体力学
實驗流體力學
실험류체역학
JOURNAL OF EXPERIMENTS IN FLUID MECHANICS
2014年
1期
89-93
,共5页
谢艳%李平%蒋鸿%王瑞波%薛江平
謝豔%李平%蔣鴻%王瑞波%薛江平
사염%리평%장홍%왕서파%설강평
跨声速风洞%测力%连续变迎角%试验技术
跨聲速風洞%測力%連續變迎角%試驗技術
과성속풍동%측력%련속변영각%시험기술
transonic wind tunnel%force measurement%continuous sweep angle of attack%test technique
在2.4m跨声速风洞开展连续变迎角试验技术研究中,遇到了3个难题:跨声速流场被持续扰动,快速精确补偿困难;试验有用信号频率与干扰信号频率产生重叠,降噪处理困难;信号间不同步对试验数据的影响增大,信号精确同步困难。采用总静压滤波优化和PID(Proportional Integral Differential)调节优化等方法提高流场快速跟随性,硬件+软件+小波等复合滤波方式进行降噪处理,并利用互相关函数实现各信号的精确同步,建立了2.4m跨声速风洞连续变迎角试验技术。使用J7等标模对该项技术进行了验证,结果表明,上述问题均得到有效解决,连续变迎角试验流场犕犪数稳定在±0.002范围内,数据的精准度达到阶梯测力试验水平。
在2.4m跨聲速風洞開展連續變迎角試驗技術研究中,遇到瞭3箇難題:跨聲速流場被持續擾動,快速精確補償睏難;試驗有用信號頻率與榦擾信號頻率產生重疊,降譟處理睏難;信號間不同步對試驗數據的影響增大,信號精確同步睏難。採用總靜壓濾波優化和PID(Proportional Integral Differential)調節優化等方法提高流場快速跟隨性,硬件+軟件+小波等複閤濾波方式進行降譟處理,併利用互相關函數實現各信號的精確同步,建立瞭2.4m跨聲速風洞連續變迎角試驗技術。使用J7等標模對該項技術進行瞭驗證,結果錶明,上述問題均得到有效解決,連續變迎角試驗流場犕犪數穩定在±0.002範圍內,數據的精準度達到階梯測力試驗水平。
재2.4m과성속풍동개전련속변영각시험기술연구중,우도료3개난제:과성속류장피지속우동,쾌속정학보상곤난;시험유용신호빈솔여간우신호빈솔산생중첩,강조처리곤난;신호간불동보대시험수거적영향증대,신호정학동보곤난。채용총정압려파우화화PID(Proportional Integral Differential)조절우화등방법제고류장쾌속근수성,경건+연건+소파등복합려파방식진행강조처리,병이용호상관함수실현각신호적정학동보,건립료2.4m과성속풍동련속변영각시험기술。사용J7등표모대해항기술진행료험증,결과표명,상술문제균득도유효해결,련속변영각시험류장비규수은정재±0.002범위내,수거적정준도체도계제측력시험수평。
The three key technical problems have be met in developing the continuous sweep-ing angle of attack test technique in 2 .4m transonic wind tunnel.First,it is difficult to compen-sate transonic flow field quickly and accurately because of persistent disturbances.Second,it is difficult to filter and denoise test data because of overlapped frequencies of useful and disturbing signals.Third,it is difficult to synchronize test data because of actual signals being not synchro-nized.In order to solve these problems,a series of research and development were carried out. Quick compensation of flow field is achieved through optimizing PID(Proportional Integral Differ-ential)parameters and optimizing filter of total and static pressure signals.Test signals are de-noised through a combined filtering approach of software,hardware and wavelet.Cross-correla-tion function is used in synchronizing wind tunnel test signals.Based on above research work,the technique of continuous sweeping angle of attack for force measurement test in 2 .4m transonic wind tunnel was achieved.This technique is verified through J7 calibration model,and test re-sults show that the technical problems mentioned above are solved effectively.Mach number con-trol precision has reached ±0.002 and the results have good consistency with those of conven-tional pitch-and-pause testing mode.