目的:探讨PET/CT图像分割技术对肺癌放疗计划制定的影响。方法对12例无转移的肺癌患者行PET/CT扫描。采用自主编写的基于PCNN模型的自动分割程序对PET靶区进行分割处理,再分别以CT图像、PET/CT图像为依据采用目测法手动勾画肿瘤靶区,以相同参数制定调强放疗计划,对比分析靶区体积和剂量分布。结果 PET自动分割靶区与PET手动勾画靶区之间未见统计学差异(P>0.05),分割方法准确可靠;与CT手动勾画靶区之间差异有统计学意义(P<0.05),前者<后者,PET/CT图像较CT能更准确的区分肿瘤与肺不张。与基于CT的放疗计划相比,PET计划正常肺组织V20、V30均有显著降低,差异均有统计学意义(P<0.05)。脊髓、心脏和食管的受量差异无统计学意义(P>0.05)。结论 PET/CT图像分割技术提高了肿瘤靶区勾画的准确性,依据分割靶区制订的放疗计划能降低正常组织受照范围,减少并发症的发生率。
目的:探討PET/CT圖像分割技術對肺癌放療計劃製定的影響。方法對12例無轉移的肺癌患者行PET/CT掃描。採用自主編寫的基于PCNN模型的自動分割程序對PET靶區進行分割處理,再分彆以CT圖像、PET/CT圖像為依據採用目測法手動勾畫腫瘤靶區,以相同參數製定調彊放療計劃,對比分析靶區體積和劑量分佈。結果 PET自動分割靶區與PET手動勾畫靶區之間未見統計學差異(P>0.05),分割方法準確可靠;與CT手動勾畫靶區之間差異有統計學意義(P<0.05),前者<後者,PET/CT圖像較CT能更準確的區分腫瘤與肺不張。與基于CT的放療計劃相比,PET計劃正常肺組織V20、V30均有顯著降低,差異均有統計學意義(P<0.05)。脊髓、心髒和食管的受量差異無統計學意義(P>0.05)。結論 PET/CT圖像分割技術提高瞭腫瘤靶區勾畫的準確性,依據分割靶區製訂的放療計劃能降低正常組織受照範圍,減少併髮癥的髮生率。
목적:탐토PET/CT도상분할기술대폐암방료계화제정적영향。방법대12례무전이적폐암환자행PET/CT소묘。채용자주편사적기우PCNN모형적자동분할정서대PET파구진행분할처리,재분별이CT도상、PET/CT도상위의거채용목측법수동구화종류파구,이상동삼수제정조강방료계화,대비분석파구체적화제량분포。결과 PET자동분할파구여PET수동구화파구지간미견통계학차이(P>0.05),분할방법준학가고;여CT수동구화파구지간차이유통계학의의(P<0.05),전자<후자,PET/CT도상교CT능경준학적구분종류여폐불장。여기우CT적방료계화상비,PET계화정상폐조직V20、V30균유현저강저,차이균유통계학의의(P<0.05)。척수、심장화식관적수량차이무통계학의의(P>0.05)。결론 PET/CT도상분할기술제고료종류파구구화적준학성,의거분할파구제정적방료계화능강저정상조직수조범위,감소병발증적발생솔。
Objective To investigate the inlfuence on radiotherapy planning of lung cancer with the PET/CT segmentation technology.Methods 12 patients with non-metastatic lung cancer were scanned by PET/CT. The PET targets were segmented by automatic segmenting program written independently based on PCNN model.According to CT images and PET/CT images, the tumor targets were delineated manually by ocular estimating, radiotherapy planning was formulated with the same parameters, the targets volume and dose distribution were compared and analyzed.Results The differences between automatic segmentation target area and manual delineation target area of PET weren’t of statistical signiifcance (P>0.05), which proved the PET automatic segmentation method was more accurate and reliable. Statistically signiifcant differences (P<0.05) existed between the PET automatic segmentation target area and CT manual delineation target area, and the former was less than the latter, which proved that PET/CT images were more accurate in distinguishing between the tumor and the atelectasis. Compared with the radiotherapy planning based on CT, PET planning signiifcantly reduced the V20 and V30 normal lung tissues, statistically signiifcant differences (P<0.05) were discovered between them. However, there were no statistical significances (P>0.05) in the quantity difference of spinal cords, hearts and esophaguses.Conclusion PET/CT image segmentation improves the accuracy of tumor target delineation. The radiotherapy planning based on target segmentation can reduce the illuminated scope of normal tissues and the incidence rate of complications.