建立了GC-MS联用分析化妆品中四种氯代烃的方法。样品中的四氯化碳、三氯乙烯、1,1,2-三氯乙烷和四氯乙烯经顶空加热提取后,用中等极性毛细管柱(HP-VOC)分离并采用质谱检测器(MS)测定。结果表明四氯化碳的标准曲线为Y=18221500X-733803,相关系数0.9994,试样3个添加水平下的回收率为71.5%~112.3%,方法检出限为0.31 mg/kg;三氯乙烯的标准曲线为Y=9633820X-338659,相关系数0.9989,试样3个添加水平下的回收率为73.8%~118.6%,方法检出限为0.83 mg/kg;1,1,2-三氯乙烷的标准曲线为Y=189350X+953532,相关系数0.9985,试样3个添加水平下的回收率为81.2%~109.6%,方法检出限为2.5 mg/kg;四氯乙烯的标准曲线为Y=5738810X-3956440,相关系数0.9979,试样3个添加水平下的回收率为75.5%~111.1%,方法检出限为0.75 mg/kg。
建立瞭GC-MS聯用分析化妝品中四種氯代烴的方法。樣品中的四氯化碳、三氯乙烯、1,1,2-三氯乙烷和四氯乙烯經頂空加熱提取後,用中等極性毛細管柱(HP-VOC)分離併採用質譜檢測器(MS)測定。結果錶明四氯化碳的標準麯線為Y=18221500X-733803,相關繫數0.9994,試樣3箇添加水平下的迴收率為71.5%~112.3%,方法檢齣限為0.31 mg/kg;三氯乙烯的標準麯線為Y=9633820X-338659,相關繫數0.9989,試樣3箇添加水平下的迴收率為73.8%~118.6%,方法檢齣限為0.83 mg/kg;1,1,2-三氯乙烷的標準麯線為Y=189350X+953532,相關繫數0.9985,試樣3箇添加水平下的迴收率為81.2%~109.6%,方法檢齣限為2.5 mg/kg;四氯乙烯的標準麯線為Y=5738810X-3956440,相關繫數0.9979,試樣3箇添加水平下的迴收率為75.5%~111.1%,方法檢齣限為0.75 mg/kg。
건립료GC-MS련용분석화장품중사충록대경적방법。양품중적사록화탄、삼록을희、1,1,2-삼록을완화사록을희경정공가열제취후,용중등겁성모세관주(HP-VOC)분리병채용질보검측기(MS)측정。결과표명사록화탄적표준곡선위Y=18221500X-733803,상관계수0.9994,시양3개첨가수평하적회수솔위71.5%~112.3%,방법검출한위0.31 mg/kg;삼록을희적표준곡선위Y=9633820X-338659,상관계수0.9989,시양3개첨가수평하적회수솔위73.8%~118.6%,방법검출한위0.83 mg/kg;1,1,2-삼록을완적표준곡선위Y=189350X+953532,상관계수0.9985,시양3개첨가수평하적회수솔위81.2%~109.6%,방법검출한위2.5 mg/kg;사록을희적표준곡선위Y=5738810X-3956440,상관계수0.9979,시양3개첨가수평하적회수솔위75.5%~111.1%,방법검출한위0.75 mg/kg。
A method for determination of four kinds of chlorinated hydrocarbons in cosmetics was established. The carbon tet-rachloride,trichlorethylene,1 ,1 ,2-trichloroethane and tetrachlorethylene in cosmetics were extracted by headspace method. Then the extracts were detected by GC-MS. The results showed that the standard curve of carbon tetrachloride was Y =18 221 500X-7 338 030,and the correlation coefficient was 0.9994,the average recovery ranged from 71.5% to 112.3% , the minimum detection limit was 0.31 mg/kg in cosmetics. The standard curve of trichlorethylene wasY= 9 633 820X-338 659,and the correlation coefficient was 0.9989,the average recovery ranged from 73.8% to 118.6% ,the minimum detec-tion limit was 0.83 mg/kg in cosmetics. The standard curve of 1 ,1 ,2-trichloroethane wasY= 1 189 350X+953 532,and the correlation coefficient was 0.9985,the average recovery ranged from 81.2% to 109.6% ,the minimum detection limit was 2.5 mg/kg in cosmetics. The standard curve of tetrachlorethylene wasY= 5 738 810X-3 956 440,and the correlation coef-ficient was 0.9979,the average recovery ranged from 75.5% to 111.1% . The minimum detection limit was 0.75 mg/kg in cosmetics.