某310 MW机组脱硝后空预器堵塞严重,严重影响机组运行的安全性与经济性,在充分调研与论证基础上实施空预器在线清洗,解决了运行中空预器严重堵塞问题,并对空预器堵塞的防范措施进行探讨。
某310 MW機組脫硝後空預器堵塞嚴重,嚴重影響機組運行的安全性與經濟性,在充分調研與論證基礎上實施空預器在線清洗,解決瞭運行中空預器嚴重堵塞問題,併對空預器堵塞的防範措施進行探討。
모310 MW궤조탈초후공예기도새엄중,엄중영향궤조운행적안전성여경제성,재충분조연여론증기출상실시공예기재선청세,해결료운행중공예기엄중도새문제,병대공예기도새적방범조시진행탐토。
A certain air preheater of 310 MW unit was seriously clogged after denitration which influenced security and economy of unit operation seriously. On the basis of thorough investigation and argumentation, the online cleaning of air preheater was conducted,and the serious congestion problem in the unit operation was solved, and the preventive measures about air preheater clogging are discussed in this paper.