自行开发设计大气颗粒物双通道采样器,通过更换粒径切割器实现对大气总悬浮颗粒物( TSP)、可吸入颗粒物( PM10)或细颗粒物( PM2?5)样品的采集。该仪器通过流量传感器、比例阀和流量控制板精确控制每个通道的采样流量,控制系统还可实时采集大气环境温度、压力、湿度、风速和风向5个气象参数,并根据环境温度、压力的变化对采样的体积流量进行补偿计算,以确保进样口体积流量恒定,保证粒径切割准确。在2011年深圳大学生运动会期间(8月12-23日)和后期(8月24日至9月4日),利用该仪器进行了大气环境野外观测实验,并对该仪器和Thermo2300采样器的结果进行了平行性分析和对比分析,其平行结果和对比结果相关系数均大于0?99。
自行開髮設計大氣顆粒物雙通道採樣器,通過更換粒徑切割器實現對大氣總懸浮顆粒物( TSP)、可吸入顆粒物( PM10)或細顆粒物( PM2?5)樣品的採集。該儀器通過流量傳感器、比例閥和流量控製闆精確控製每箇通道的採樣流量,控製繫統還可實時採集大氣環境溫度、壓力、濕度、風速和風嚮5箇氣象參數,併根據環境溫度、壓力的變化對採樣的體積流量進行補償計算,以確保進樣口體積流量恆定,保證粒徑切割準確。在2011年深圳大學生運動會期間(8月12-23日)和後期(8月24日至9月4日),利用該儀器進行瞭大氣環境野外觀測實驗,併對該儀器和Thermo2300採樣器的結果進行瞭平行性分析和對比分析,其平行結果和對比結果相關繫數均大于0?99。
자행개발설계대기과립물쌍통도채양기,통과경환립경절할기실현대대기총현부과립물( TSP)、가흡입과립물( PM10)혹세과립물( PM2?5)양품적채집。해의기통과류량전감기、비례벌화류량공제판정학공제매개통도적채양류량,공제계통환가실시채집대기배경온도、압력、습도、풍속화풍향5개기상삼수,병근거배경온도、압력적변화대채양적체적류량진행보상계산,이학보진양구체적류량항정,보증립경절할준학。재2011년심수대학생운동회기간(8월12-23일)화후기(8월24일지9월4일),이용해의기진행료대기배경야외관측실험,병대해의기화Thermo2300채양기적결과진행료평행성분석화대비분석,기평행결과화대비결과상관계수균대우0?99。
A dual-channel aerosol sampler was recently designed and manufactured by the Group in the Division of Atmospheric Environmental Sciences, CRE, UCAS. It is available to collecting the aerosol sample of TSP, PM10 , or PM2?5 via switching the particle size selector easily. The flow rate of each channel of the sampler is accurately controlled by proportional valve, flow sensor, and single chip microcomputer and automatically corrected by pressure and temperature compensating. The application of advanced single chip microcomputer control and LCD Panel technique greatly optimized its operation interface making its function control and parameter display panel conveniently. In addition, the meteorological parameters of temperature, atmospheric pressure, relative humidity, wind direction and speed are also measured by this sampler. This sampler has already been applied in a sampling campaign during (from 12th August to 23th August, 2011) and after (from 24th August to 4th September, 2011) the 2011 Shenzhen UNIVERSIADE. Results obtained from this sampler and commercialized sampler ( Thermo2300 ) are analysed indicating that our aerosol sampler has stable and reliable performance (r>0?99).