目的:研究快速、经济、准确、易普及的测定肺动脉压力的实验方法。方法:通过自制聚乙烯( po-lyethylene , PE)导管,连接PowerLab多通道生物信号记录系统,肝素化后经颈外静脉插管,经上腔静脉、右心室进入肺动脉,记录实时波形及压力。通过解剖明确出现不同波形时的导管位置及朝向,从而指导导管推送过程。结果:通过自制PE导管。采用改良右心导管法对120只Sprague-Dawley(SD)大鼠进行肺动脉插管。采用该法从插管开始至到达肺动脉平均耗时2 min,成功率95%。结论:使用自制的PE导管经改良右心导管法测定肺动脉压力具有成功率高、数据准确、操作省时、方法易掌握的优点,是一种较好的测定大鼠肺动脉压力的实验方法。
目的:研究快速、經濟、準確、易普及的測定肺動脈壓力的實驗方法。方法:通過自製聚乙烯( po-lyethylene , PE)導管,連接PowerLab多通道生物信號記錄繫統,肝素化後經頸外靜脈插管,經上腔靜脈、右心室進入肺動脈,記錄實時波形及壓力。通過解剖明確齣現不同波形時的導管位置及朝嚮,從而指導導管推送過程。結果:通過自製PE導管。採用改良右心導管法對120隻Sprague-Dawley(SD)大鼠進行肺動脈插管。採用該法從插管開始至到達肺動脈平均耗時2 min,成功率95%。結論:使用自製的PE導管經改良右心導管法測定肺動脈壓力具有成功率高、數據準確、操作省時、方法易掌握的優點,是一種較好的測定大鼠肺動脈壓力的實驗方法。
목적:연구쾌속、경제、준학、역보급적측정폐동맥압력적실험방법。방법:통과자제취을희( po-lyethylene , PE)도관,련접PowerLab다통도생물신호기록계통,간소화후경경외정맥삽관,경상강정맥、우심실진입폐동맥,기록실시파형급압력。통과해부명학출현불동파형시적도관위치급조향,종이지도도관추송과정。결과:통과자제PE도관。채용개량우심도관법대120지Sprague-Dawley(SD)대서진행폐동맥삽관。채용해법종삽관개시지도체폐동맥평균모시2 min,성공솔95%。결론:사용자제적PE도관경개량우심도관법측정폐동맥압력구유성공솔고、수거준학、조작성시、방법역장악적우점,시일충교호적측정대서폐동맥압력적실험방법。
AIM:To explore a fast, economical, accurate and widely used experimental method for the meas-urement of pulmonary artery pressure .METHODS: A home-made polyethylene ( PE ) catheter was connected with the PowerLab 8/35 multi-channel biological signal recording system , and then the pulmonary artery pressure was measured by right heart catheterization.The catheter, prefilled with heparin, was introduced through external jugular vein , precava, the right ventricle and the pulmonary artery .We recorded the real-time wave during the whole procedure .In this study, we anatomized the animals in every stage of the procedure to determine the position of the catheter and the direction of the end of the catheter.The procedure of the catheterization was guided by analyzing the real-time wave.RESULTS: Using this home-made PE tube and the meliorative technique , we performed the right heart catheterization in 120 Sprague-Dawley rats with the success rate of 95%.The procedure of right heart catheterization took us about 2 min from the external jugular vein to pulmonary artery in average .CONCLUSION: Measuring the pulmonary artery pressure through this meliorative tech-nique with a home-made PE pipe in rats not only achieves a high success rate but also saves time .Moreover, this method can be popularized easily as a good and feasible way for measuring pulmonary artery pressure in rats .