机械工程与自动化
機械工程與自動化
궤계공정여자동화
MECHANICAL ENGINEERING & AUTOMATION
2014年
2期
142-143,146
,共3页
超临界%协调控制%变负荷前馈
超臨界%協調控製%變負荷前饋
초림계%협조공제%변부하전궤
supercritical%coordinated control system%feedforward
针对崇信发电厂660MW超临界直流机组协调控制系统进行了分析,优化了机组协调控制方案。实践证明,投产后机组运行稳定,调节品质良好,在40%~100%MCR(额定负荷)段具有优良的负荷适应性,为大型超临界机组协调控制系统的设计提供了很好的借鉴。
針對崇信髮電廠660MW超臨界直流機組協調控製繫統進行瞭分析,優化瞭機組協調控製方案。實踐證明,投產後機組運行穩定,調節品質良好,在40%~100%MCR(額定負荷)段具有優良的負荷適應性,為大型超臨界機組協調控製繫統的設計提供瞭很好的藉鑒。
침대숭신발전엄660MW초림계직류궤조협조공제계통진행료분석,우화료궤조협조공제방안。실천증명,투산후궤조운행은정,조절품질량호,재40%~100%MCR(액정부하)단구유우량적부하괄응성,위대형초림계궤조협조공제계통적설계제공료흔호적차감。
The coordinated control system for 660 MW supercritical unit is analyzed ,it has been optimized during the commissioning of the unit .The practice result shows that the unit is stability and the regulating quality is excellent ,in the load range of 40% ~100% MCR ,the unit makes fine in the adaptability to the variety of load .This work provides a good reference for the design of the coordinated control system of large supercritical unit .