采用等效热降理论,对哈尔滨汽轮机厂制造的300 MW亚临界直接空冷机组电泵改为汽泵可行性进行了探讨。分析计算结果表明,电泵改汽泵后供电煤耗降低幅度较小,经济效益不明显,在短期内设备投资无法收回。
採用等效熱降理論,對哈爾濱汽輪機廠製造的300 MW亞臨界直接空冷機組電泵改為汽泵可行性進行瞭探討。分析計算結果錶明,電泵改汽泵後供電煤耗降低幅度較小,經濟效益不明顯,在短期內設備投資無法收迴。
채용등효열강이론,대합이빈기륜궤엄제조적300 MW아림계직접공랭궤조전빙개위기빙가행성진행료탐토。분석계산결과표명,전빙개기빙후공전매모강저폭도교소,경제효익불명현,재단기내설비투자무법수회。
In this paper,equivalent enthalpy drop theory was adopted to analyse the feasibility of replacing electric pump with steam feed water pump for 300 MW subcritical direct air cooling unit manufactured by Harbin Steam Turbine Company. The analysis results show that the coal consumption after the reformation reduced not obviously so that the cost in the reformation can not be recovered in the short term.