利用油中溶解气体分析技术,结合高压试验进行变压器故障诊断,准确地发现了变压器的故障性质和部位,并进行了相应的处理,保障了电网的安全运行。
利用油中溶解氣體分析技術,結閤高壓試驗進行變壓器故障診斷,準確地髮現瞭變壓器的故障性質和部位,併進行瞭相應的處理,保障瞭電網的安全運行。
이용유중용해기체분석기술,결합고압시험진행변압기고장진단,준학지발현료변압기적고장성질화부위,병진행료상응적처리,보장료전망적안전운행。
The nature and position of transformer faults were identified accurately through dissolved gas analysis technique and high voltage test for fault diagnosis,and treatments were done correspondingly,which ensures the safe operation of power grid.