洪庆山%张晓玲%胡志刚%刘永熙%贺小明%郭雪贞
洪慶山%張曉玲%鬍誌剛%劉永熙%賀小明%郭雪貞
홍경산%장효령%호지강%류영희%하소명%곽설정
新生儿%先天性心脏病%体层摄影术,X线计算机%超声心动图
新生兒%先天性心髒病%體層攝影術,X線計算機%超聲心動圖
신생인%선천성심장병%체층섭영술,X선계산궤%초성심동도
Newborn%Congenital heart disease%Tomography,X-ray computed%Echocardiography
目的:探讨128层MSCT在新生儿复杂型先天性心脏病(CCHD)的应用价值。方法对我院手术证实的35例新生儿CCHD进行回顾性心电门控128层MSCT扫描,分析新生儿心脏CT检查特殊的扫描技术,并与超声心动图比较。结果所有新生儿均成功完成MSCT心脏扫描。本组35例新生儿复杂型CHD中,MSCT共检出93个心内外结构异常,超声心动图则检出86个,两种检查方法对于显示畸形部位数目的差异没有统计学意义(P=0.205)。但超声比MSCT多发现3例房/室间隔缺损及2例肺动脉瓣狭窄,而MSCT比超声心动图多发现12例心外血管畸形。结论 MSCT回顾性心电门控扫描技术能较好评价新生儿复杂型CHD,弥补超声心动图对心外血管畸形显示能力低的缺点。
目的:探討128層MSCT在新生兒複雜型先天性心髒病(CCHD)的應用價值。方法對我院手術證實的35例新生兒CCHD進行迴顧性心電門控128層MSCT掃描,分析新生兒心髒CT檢查特殊的掃描技術,併與超聲心動圖比較。結果所有新生兒均成功完成MSCT心髒掃描。本組35例新生兒複雜型CHD中,MSCT共檢齣93箇心內外結構異常,超聲心動圖則檢齣86箇,兩種檢查方法對于顯示畸形部位數目的差異沒有統計學意義(P=0.205)。但超聲比MSCT多髮現3例房/室間隔缺損及2例肺動脈瓣狹窄,而MSCT比超聲心動圖多髮現12例心外血管畸形。結論 MSCT迴顧性心電門控掃描技術能較好評價新生兒複雜型CHD,瀰補超聲心動圖對心外血管畸形顯示能力低的缺點。
목적:탐토128층MSCT재신생인복잡형선천성심장병(CCHD)적응용개치。방법대아원수술증실적35례신생인CCHD진행회고성심전문공128층MSCT소묘,분석신생인심장CT검사특수적소묘기술,병여초성심동도비교。결과소유신생인균성공완성MSCT심장소묘。본조35례신생인복잡형CHD중,MSCT공검출93개심내외결구이상,초성심동도칙검출86개,량충검사방법대우현시기형부위수목적차이몰유통계학의의(P=0.205)。단초성비MSCT다발현3례방/실간격결손급2례폐동맥판협착,이MSCT비초성심동도다발현12례심외혈관기형。결론 MSCT회고성심전문공소묘기술능교호평개신생인복잡형CHD,미보초성심동도대심외혈관기형현시능력저적결점。
Objective To evaluate of the application of 128-slice CT in complex congenital heart disease(CCHD)of neonates.Methods 35 neonates with CCHD underwent 128-slice CT using retrospective ECG-gating.The CT was compared with echocardiography.Results In 35 patients,there was no significant difference between CT(93)and echocardiography(86)for demonstrating intra- and extra-cardiac abnormalities(P=0.205).Three ventricular/atria sepal defects and 2 pulmonary valvular sclerosis were depicted only on echocardiography whereas 12 extra-cardiac vascular abnormalities were seen only on CT.Conclusion Retrospective ECG-gated 128-slice CT complements echocardiography for evaluating extra-cardiac vascular abnormalities in CCHD.