computer-alided software%computed tomography%volumetry%liver
目的:探讨3D-doctor 软件在 MSCT 肝脏体积测量的应用价值。方法成年巴马公猪1头行 CT 扫描后,分别用 GE ADW4.4工作站软件、3D-doctor 软件测量肝脏 CT 体积及溢水法测量离体肝脏体积。收集成年受试者32例,分别用 GE ADW4.4工作站软件及3D-doctor 软件测量肝脏体积。32例受试者中随机选取15例进行重复测量。结果分别用 GE ADW4.4工作站、3D-doctor 软件和溢水法测量猪肝脏体积为643.47 cm3、670.22 cm3、660.00 cm3。以溢水法测量结果为标准,3D-doctor 软件及 GE ADW4.4工作站软件测量肝脏体积结果差异率分别为2.5%、1.5%。分别用 GE ADW4.4工作站软件、3D-doctor 软件测量32例受试者肝脏体积均数为(1024.68±328.59)cm3、(1026.43±327.67)cm3。2种测量方法所得肝脏体积之间无差异(t =-0.403,P=0.690)。经 Bland-Altman 图分析,2种方法测量结果一致性较好。使用3D-doctor 软件,同一操作者重复测量15例受试者肝脏体积及2位操作者之间测量结果组内相关系数(intraclass correlation coefficient,ICC)为1,Cronbach’s alpha 系数为1。结论3D-doctor 软件在测量 MSCT 肝脏体积上具有可靠性、一致性及重复性,能为临床提供参考数据指导诊断与治疗。
目的:探討3D-doctor 軟件在 MSCT 肝髒體積測量的應用價值。方法成年巴馬公豬1頭行 CT 掃描後,分彆用 GE ADW4.4工作站軟件、3D-doctor 軟件測量肝髒 CT 體積及溢水法測量離體肝髒體積。收集成年受試者32例,分彆用 GE ADW4.4工作站軟件及3D-doctor 軟件測量肝髒體積。32例受試者中隨機選取15例進行重複測量。結果分彆用 GE ADW4.4工作站、3D-doctor 軟件和溢水法測量豬肝髒體積為643.47 cm3、670.22 cm3、660.00 cm3。以溢水法測量結果為標準,3D-doctor 軟件及 GE ADW4.4工作站軟件測量肝髒體積結果差異率分彆為2.5%、1.5%。分彆用 GE ADW4.4工作站軟件、3D-doctor 軟件測量32例受試者肝髒體積均數為(1024.68±328.59)cm3、(1026.43±327.67)cm3。2種測量方法所得肝髒體積之間無差異(t =-0.403,P=0.690)。經 Bland-Altman 圖分析,2種方法測量結果一緻性較好。使用3D-doctor 軟件,同一操作者重複測量15例受試者肝髒體積及2位操作者之間測量結果組內相關繫數(intraclass correlation coefficient,ICC)為1,Cronbach’s alpha 繫數為1。結論3D-doctor 軟件在測量 MSCT 肝髒體積上具有可靠性、一緻性及重複性,能為臨床提供參攷數據指導診斷與治療。
목적:탐토3D-doctor 연건재 MSCT 간장체적측량적응용개치。방법성년파마공저1두행 CT 소묘후,분별용 GE ADW4.4공작참연건、3D-doctor 연건측량간장 CT 체적급일수법측량리체간장체적。수집성년수시자32례,분별용 GE ADW4.4공작참연건급3D-doctor 연건측량간장체적。32례수시자중수궤선취15례진행중복측량。결과분별용 GE ADW4.4공작참、3D-doctor 연건화일수법측량저간장체적위643.47 cm3、670.22 cm3、660.00 cm3。이일수법측량결과위표준,3D-doctor 연건급 GE ADW4.4공작참연건측량간장체적결과차이솔분별위2.5%、1.5%。분별용 GE ADW4.4공작참연건、3D-doctor 연건측량32례수시자간장체적균수위(1024.68±328.59)cm3、(1026.43±327.67)cm3。2충측량방법소득간장체적지간무차이(t =-0.403,P=0.690)。경 Bland-Altman 도분석,2충방법측량결과일치성교호。사용3D-doctor 연건,동일조작자중복측량15례수시자간장체적급2위조작자지간측량결과조내상관계수(intraclass correlation coefficient,ICC)위1,Cronbach’s alpha 계수위1。결론3D-doctor 연건재측량 MSCT 간장체적상구유가고성、일치성급중복성,능위림상제공삼고수거지도진단여치료。
Objective To evaluate the value of liver volume measurement with 3D-doctor computer-aided software at MSCT. Methods One male adult Bama mini pig was underwent CT scan.Pig’s liver CT volume was measured with GE ADW4.4 workstat-tion,3D-doctor computer-aided software,respectively.In vitro,liver volume was measured by drainage.Collected 32 patients that underwent CT scan.All patients’liver CT volumes were measured with GE ADW4.4 workstattion,3D-doctor computer-aided soft-ware,respectively.Randomly selected 1 5 patients in 32 subjects,and used 3D-doctor computer-aided software to repeated measure the liver volume by two operators and one operator at different time.Results A Bama mini pig’s liver volume,measured by ADW4.4 workstattion,3D-doctor computer-aided software and drainage,was 643.47 cm3 ,670.22 cm3 ,660.00 cm3 ,respectively. Used the liver volume of drainage as the standard to compare,the differences liver volume of 3D-doctor computer-aided software and ADW4.4 workstattion was 2.5%,1.5%,respectively.Thirty-two subjects’mean liver volume,measured by ADW4.4 workstat-tion,3D-doctor computer-aided software,were (1 024.68 ± 328.59)cm3 、(1 026.43 ± 327.67)cm3 ,respectively.There was no statistically significant different between that of the two measurement methods(t = -0.403,P =0.690).Liver volume with two measurement methods was good consistency by Bland-Altman method.Used 3D-doctor computer-aided software to repeated measure the liver volume by two operators and one operator at different time,the ICC was 1 and Cronbach's alpha was 1.Conclusion It is re-liable,consistent and reproducibile by using 3D-doctor computer-aided software to measure liver volume at MSCT.