ICP—AES%测定%金属钙
ICP—AES%測定%金屬鈣
ICP—AES%측정%금속개
ICP-AES%determination%calcium metal
研究了ICP-AES法测定金属钙中铁、镍、铜、锰、镁、硅、铝的样品处理和分析条件。金属钙线经表面处理和制样后,马上用(1+1)硝酸溶解、定容,工作曲线不需作基体匹配。在选定的分析谱线和仪器条件下测量,相对标准偏差为1.3%~13.1%,回收率92.2%~107%。本方法简便、快速、准确,可以满足生产需求。
研究瞭ICP-AES法測定金屬鈣中鐵、鎳、銅、錳、鎂、硅、鋁的樣品處理和分析條件。金屬鈣線經錶麵處理和製樣後,馬上用(1+1)硝痠溶解、定容,工作麯線不需作基體匹配。在選定的分析譜線和儀器條件下測量,相對標準偏差為1.3%~13.1%,迴收率92.2%~107%。本方法簡便、快速、準確,可以滿足生產需求。
연구료ICP-AES법측정금속개중철、얼、동、맹、미、규、려적양품처리화분석조건。금속개선경표면처리화제양후,마상용(1+1)초산용해、정용,공작곡선불수작기체필배。재선정적분석보선화의기조건하측량,상대표준편차위1.3%~13.1%,회수솔92.2%~107%。본방법간편、쾌속、준학,가이만족생산수구。
The conditions of samples pretreated and analysis in determination of iron, nickel, copper, manganese, magnesium, silicon, aluminum in calcium metal by ICP-AES method was studied. Calcium metailine after surface treatment and preparation, then immediately dissolved with 1 + 1 nitric acid, constant volume. The calibration curve do not need to correct by using matrix matching. The samples was measured under the conditions by the selected analysis spectral lines and instruments , the relative standard deviation was in the range of 1.3% - 13.1%, the recovery are between 92.2% -107.0% . The method is simple, rapid, accurate, may satisfy the production requirement.