徐金龙%华斌%杨树洁%史亚晓%李展江
徐金龍%華斌%楊樹潔%史亞曉%李展江
서금룡%화빈%양수길%사아효%리전강
硅锰合金%硼%电感耦合等离子体发射光谱法
硅錳閤金%硼%電感耦閤等離子體髮射光譜法
규맹합금%붕%전감우합등리자체발사광보법
Silicon Manganese Alloy%Boron%ICP-OES
建立了电感耦合等离子体发射光谱法测定锰硅合金中硼含量的方法。经过实验比较分析,选定前处理采用硝酸-氢氟酸分解样品,以甘露醇作络合保护剂,用标准加入法测定样品中硼含量,相对标准偏差为4.51%,结果令人满意。
建立瞭電感耦閤等離子體髮射光譜法測定錳硅閤金中硼含量的方法。經過實驗比較分析,選定前處理採用硝痠-氫氟痠分解樣品,以甘露醇作絡閤保護劑,用標準加入法測定樣品中硼含量,相對標準偏差為4.51%,結果令人滿意。
건립료전감우합등리자체발사광보법측정맹규합금중붕함량적방법。경과실험비교분석,선정전처리채용초산-경불산분해양품,이감로순작락합보호제,용표준가입법측정양품중붕함량,상대표준편차위4.51%,결과령인만의。
Detection method of boron content in manganese silicon alloy by ICP-OES was set up. After a comparative analysis of experimentation, it was worked out that the sample was pretreated with nitric acid-hydrofluoric acid decomposition, and that mannitol served as a complexing protector. The boron content was determined using ICP-OES in spiked samples. The relative standard deviation was 4.51%and the result was satisfactory.