投切电容器组%智能开关%同步开关%高压无功补偿
投切電容器組%智能開關%同步開關%高壓無功補償
투절전용기조%지능개관%동보개관%고압무공보상
switching capacitors%intelligent switch%synchronous switch%high voltage reactive powercompensation
通过分析多种投切电容器组开关电路,在改进部分电路的基础上开发出一种新型高压无功补偿装置。该无功补偿装置具备以下显著优点:可快速跟踪系统无功功率的变化,合闸时能有效避免电流冲击,分闸时能有效避免重燃,合闸和分闸主回路特性如同晶闸管的工作特性,但使用成本和能耗却比晶闸管低。
通過分析多種投切電容器組開關電路,在改進部分電路的基礎上開髮齣一種新型高壓無功補償裝置。該無功補償裝置具備以下顯著優點:可快速跟蹤繫統無功功率的變化,閤閘時能有效避免電流遲擊,分閘時能有效避免重燃,閤閘和分閘主迴路特性如同晶閘管的工作特性,但使用成本和能耗卻比晶閘管低。
통과분석다충투절전용기조개관전로,재개진부분전로적기출상개발출일충신형고압무공보상장치。해무공보상장치구비이하현저우점:가쾌속근종계통무공공솔적변화,합갑시능유효피면전류충격,분갑시능유효피면중연,합갑화분갑주회로특성여동정갑관적공작특성,단사용성본화능모각비정갑관저。
By analyzing a variety of capacitor bank switching circuits, a new high voltage reactive power compensation device was developed based on improvement of part circuits. The new device has some distinct advantages, such as quick tracking of change of capacitive reactive power, current impact can be avoided effectively, and retriggering can be effectively prevented when switching off. Working characteristics are like as thyristor, but using cost and energy consumption are lower than thyristor.