中国医药科学
中國醫藥科學
중국의약과학
CHINA MEDICINE AND PHARMACY
2013年
14期
10-12
,共3页
王新亮%郑民庆%侯之启%陈铭
王新亮%鄭民慶%侯之啟%陳銘
왕신량%정민경%후지계%진명
前交叉韧带%关节镜检查%重建
前交扠韌帶%關節鏡檢查%重建
전교차인대%관절경검사%중건
Anterior cruciate ligament%Arthroscopy%Reconstruction
目的对比研究关节镜下自体腘绳肌腱单束移植重建前交叉韧带中分别应用横穿钉/膨胀钉固定股骨/胫骨隧道与应用可吸收界面螺钉(Bioscrew)固定的临床效果。方法将68例前交叉韧带断裂的患者分为两组:A组33例采用Rigidfix与Intrafix固定腘绳肌腱重建前交叉韧带;B组35例采用Bioscrew固定腘绳肌腱重建前交叉韧带。术后按照同样康复计划进行康复训练。结果两组随访12~23个月,以术后12个月为参照点,两组膝关节活动度恢复良好,无主动伸直障碍,A组2例、B组3例患者出现隐神经损伤症状。术后Lysholm评分A组为(93.7±0.8)分,B组为(90.1±3.6)分,两组间手术后对比差异无统计学意义(P>0.05),组内比较手术前后Lysholm评分差异有统计学意义(P<0.05)。结论关节镜下应用Rigidfix及Intrafix固定腘绳肌腱重建前交叉韧带固定牢固愈合可靠,与Bioscrew的临床效果相当,并发症少,避免了肌腱切割、偏心固定、螺钉断裂等问题,值得临床推广。
目的對比研究關節鏡下自體腘繩肌腱單束移植重建前交扠韌帶中分彆應用橫穿釘/膨脹釘固定股骨/脛骨隧道與應用可吸收界麵螺釘(Bioscrew)固定的臨床效果。方法將68例前交扠韌帶斷裂的患者分為兩組:A組33例採用Rigidfix與Intrafix固定腘繩肌腱重建前交扠韌帶;B組35例採用Bioscrew固定腘繩肌腱重建前交扠韌帶。術後按照同樣康複計劃進行康複訓練。結果兩組隨訪12~23箇月,以術後12箇月為參照點,兩組膝關節活動度恢複良好,無主動伸直障礙,A組2例、B組3例患者齣現隱神經損傷癥狀。術後Lysholm評分A組為(93.7±0.8)分,B組為(90.1±3.6)分,兩組間手術後對比差異無統計學意義(P>0.05),組內比較手術前後Lysholm評分差異有統計學意義(P<0.05)。結論關節鏡下應用Rigidfix及Intrafix固定腘繩肌腱重建前交扠韌帶固定牢固愈閤可靠,與Bioscrew的臨床效果相噹,併髮癥少,避免瞭肌腱切割、偏心固定、螺釘斷裂等問題,值得臨床推廣。
목적대비연구관절경하자체객승기건단속이식중건전교차인대중분별응용횡천정/팽창정고정고골/경골수도여응용가흡수계면라정(Bioscrew)고정적림상효과。방법장68례전교차인대단렬적환자분위량조:A조33례채용Rigidfix여Intrafix고정객승기건중건전교차인대;B조35례채용Bioscrew고정객승기건중건전교차인대。술후안조동양강복계화진행강복훈련。결과량조수방12~23개월,이술후12개월위삼조점,량조슬관절활동도회복량호,무주동신직장애,A조2례、B조3례환자출현은신경손상증상。술후Lysholm평분A조위(93.7±0.8)분,B조위(90.1±3.6)분,량조간수술후대비차이무통계학의의(P>0.05),조내비교수술전후Lysholm평분차이유통계학의의(P<0.05)。결론관절경하응용Rigidfix급Intrafix고정객승기건중건전교차인대고정뢰고유합가고,여Bioscrew적림상효과상당,병발증소,피면료기건절할、편심고정、라정단렬등문제,치득림상추엄。
Objective To observe the clinical outcome of arthroscopic anterior cruciate ligament(ACL)single bundle reconstruction with Rigidfix /Intrafix between Bioscrew. Methods A total of 68 cases were involved in this retrospective study and were divided into two groups.33 cases underwent reconstruction with Rigidfix and Intrafix and 35 cases treated with Bioscrew. The postoperative protocols of both groups were similar.The follow-up ranged from 12 to 23 months.The Lysholm scores was recorded and compared preoperatively and 12-months postoperatively. Results The postoperative range of motion recovered well and no extension lag were found.There are 2 and 3 cases developed symptoms of saphenous nerve injury respectively to the two groups.The postoperative Lysholm scores were(93.7±0.8) and (90.1±3.6) respectively and had no statistical difference as well as the preoperative comparison.However,the postoperative and preoperative Lysholm scores of each group had statistical differences. Conclusion Arthroscopic anterior cruciate ligament(ACL)reconstruction with Rigidfix and Intrafix is safe,reliable.The clinical outcome of them is similar to Biocscrew.There are fewer complications. This is an excellent choice of surgeons.