科技创新导报
科技創新導報
과기창신도보
SCIENCE AND TECHNOLOGY CONSULTING HERALD
2012年
24期
8-9
,共2页
伏安法%电阻%误差分析%误差控制
伏安法%電阻%誤差分析%誤差控製
복안법%전조%오차분석%오차공제
voltammetry Method%Resistances Error Analysis%Error Control
本文对伏安法测电阻的两种方法利用数学图像进行了定量的分析,总结出了待测电阻、电表内阻与测量结果相对误差的内在联系及其变化规律,阐明了如何控制和减小测量误差,并对采用内接法或外接法的判别条件进行了量化。
本文對伏安法測電阻的兩種方法利用數學圖像進行瞭定量的分析,總結齣瞭待測電阻、電錶內阻與測量結果相對誤差的內在聯繫及其變化規律,闡明瞭如何控製和減小測量誤差,併對採用內接法或外接法的判彆條件進行瞭量化。
본문대복안법측전조적량충방법이용수학도상진행료정량적분석,총결출료대측전조、전표내조여측량결과상대오차적내재련계급기변화규률,천명료여하공제화감소측량오차,병대채용내접법혹외접법적판별조건진행료양화。
this paper analyzes the two methods of Measuring the inner relationship of resistance to be measured, internal At the same time, it puts forward the ways to control and methods quantitative. Besistance by voltammetry through the image of mathematics, finds out resistance of ammeter and measurement error, and their law of changing. reduce the error, and makes the standards of inner and out connecting