为测试开关电源的性能指标.设计了一种基于LM3S8962的简易恒流电子负载.该系统以LM3S8962单片机作为核心控制器.产生D,A输出信号加至功率MOS管IRF540的栅极.通过PI调节改变功率管的栅压从而控制其导通电阻,同时通过采样反馈电路检测端口电压及电流,经A/D转换后送给单片机,形成对电源端口电流的闭环控制.使负载上的电流保持相对恒定.该装置可通过键盘设定输出电流值.可调范围在100-1000mA之间设置,分辨率为10mA,可检测被测电源电流值、电压值等参数,并通过LCD显示,系统具备过压保护功能.该装置结构简单,操作方便,显示界面直观明了.测试结果表明,该电子负载恒流效果良好,系统误差在±1%范围之内.
為測試開關電源的性能指標.設計瞭一種基于LM3S8962的簡易恆流電子負載.該繫統以LM3S8962單片機作為覈心控製器.產生D,A輸齣信號加至功率MOS管IRF540的柵極.通過PI調節改變功率管的柵壓從而控製其導通電阻,同時通過採樣反饋電路檢測耑口電壓及電流,經A/D轉換後送給單片機,形成對電源耑口電流的閉環控製.使負載上的電流保持相對恆定.該裝置可通過鍵盤設定輸齣電流值.可調範圍在100-1000mA之間設置,分辨率為10mA,可檢測被測電源電流值、電壓值等參數,併通過LCD顯示,繫統具備過壓保護功能.該裝置結構簡單,操作方便,顯示界麵直觀明瞭.測試結果錶明,該電子負載恆流效果良好,繫統誤差在±1%範圍之內.
위측시개관전원적성능지표.설계료일충기우LM3S8962적간역항류전자부재.해계통이LM3S8962단편궤작위핵심공제기.산생D,A수출신호가지공솔MOS관IRF540적책겁.통과PI조절개변공솔관적책압종이공제기도통전조,동시통과채양반궤전로검측단구전압급전류,경A/D전환후송급단편궤,형성대전원단구전류적폐배공제.사부재상적전류보지상대항정.해장치가통과건반설정수출전류치.가조범위재100-1000mA지간설치,분변솔위10mA,가검측피측전원전류치、전압치등삼수,병통과LCD현시,계통구비과압보호공능.해장치결구간단,조작방편,현시계면직관명료.측시결과표명,해전자부재항류효과량호,계통오차재±1%범위지내.
To detect the reliability and properties of switching power supply system, an electronic load working in constant current mode is designed and realized. In the system, a microprocessor of LM3S8962 is used as the core mi- crocontroller, the output signal from D/A is inputted to the gate of the power MOS transistor (IRF540) through a PI regulator and the on-resistance of IRF540 can be controlled by adjusting the gate voltage. In addition, the terminal current can be kept in a constant value by using a close-loop control, in which the terminal current and voltage are measured through a sample-hold circuit and then fed back to LM3S8962 through an A/D converter. The output current of the system can be set ranging from 100 to 1 000 mA with precision of 10 mA, and can be inputted from the key- board. The actual voltage and current can be also measured under an overvoltage protection and then displayed in LCD. Moreover, the designed equipment is characterized by simple structure, friendly interface and convenient opera- tion. The measurement results indicate the equipment enjoys high precision and the error between the set and actual value is less than ±1%.