船电技术
船電技術
선전기술
2012年
10期
49-52
,共4页
潘德华%徐正喜%李文华%吴大立
潘德華%徐正喜%李文華%吳大立
반덕화%서정희%리문화%오대립
发电机%并车%二次回路%故障诊断
髮電機%併車%二次迴路%故障診斷
발전궤%병차%이차회로%고장진단
generator unit%parallel connection%secondary circuit%fault diagnosis
以某船发电机并车回路二次侧故障为例,阐明了其因转换继电器触点未断开引发电压互感器烧毁的故障机理,并针对故障提出了相应的对策,可为同类故障的预防和抢修提供参考。
以某船髮電機併車迴路二次側故障為例,闡明瞭其因轉換繼電器觸點未斷開引髮電壓互感器燒燬的故障機理,併針對故障提齣瞭相應的對策,可為同類故障的預防和搶脩提供參攷。
이모선발전궤병차회로이차측고장위례,천명료기인전환계전기촉점미단개인발전압호감기소훼적고장궤리,병침대고장제출료상응적대책,가위동류고장적예방화창수제공삼고。
By taking the secondary circuit fault of a ship’s generator unit as example, the fault mechanics is explained, whoes voltage transforms burning-out is due to unbroken relay contact. The solution is proposed, which can be referenced by precaution and recovery of like faults.