目的:探讨分离胶管、肝素锂管与普通干燥管(加盖与不加盖)四种试管对测定血浆(血清)二氧化碳的影响。方法用四种试管分装同一标本,通过加盖、不加盖与控制时间,分析不同条件下各管二氧化碳测定结果的差别。结果 C O2测定的三种加盖管(分离胶管、肝素锂管与普通干燥管)37℃水浴3小时内同一时间段间结果无显著性差异,而不加盖普通干燥管各时间段的C O2值比各加盖管的各时间段值低,有极显著性差异,且各管C O2测定结果随放置时间延长而逐渐下降。结论分离胶管与肝素锂管能够比不加盖普通干燥管更好地防止CO2的丢失,且管中的化学成份对CO2结果影响小,并且可以迅速分离血清(血浆)进行检测,因此分离胶管与肝素锂管比普通干燥管更适合CO2的检测。
目的:探討分離膠管、肝素鋰管與普通榦燥管(加蓋與不加蓋)四種試管對測定血漿(血清)二氧化碳的影響。方法用四種試管分裝同一標本,通過加蓋、不加蓋與控製時間,分析不同條件下各管二氧化碳測定結果的差彆。結果 C O2測定的三種加蓋管(分離膠管、肝素鋰管與普通榦燥管)37℃水浴3小時內同一時間段間結果無顯著性差異,而不加蓋普通榦燥管各時間段的C O2值比各加蓋管的各時間段值低,有極顯著性差異,且各管C O2測定結果隨放置時間延長而逐漸下降。結論分離膠管與肝素鋰管能夠比不加蓋普通榦燥管更好地防止CO2的丟失,且管中的化學成份對CO2結果影響小,併且可以迅速分離血清(血漿)進行檢測,因此分離膠管與肝素鋰管比普通榦燥管更適閤CO2的檢測。
목적:탐토분리효관、간소리관여보통간조관(가개여불가개)사충시관대측정혈장(혈청)이양화탄적영향。방법용사충시관분장동일표본,통과가개、불가개여공제시간,분석불동조건하각관이양화탄측정결과적차별。결과 C O2측정적삼충가개관(분리효관、간소리관여보통간조관)37℃수욕3소시내동일시간단간결과무현저성차이,이불가개보통간조관각시간단적C O2치비각가개관적각시간단치저,유겁현저성차이,차각관C O2측정결과수방치시간연장이축점하강。결론분리효관여간소리관능구비불가개보통간조관경호지방지CO2적주실,차관중적화학성빈대CO2결과영향소,병차가이신속분리혈청(혈장)진행검측,인차분리효관여간소리관비보통간조관경괄합CO2적검측。
Objective: To investigate the impact on four kinds of tubes including separation gel coagulation promoting tubes, heparin lithium coagulation promoting tubes and traditional drying tube(closed and open ) on plasma (serum) carbon dioxide determining. Methods: Analysis the difference on measurements of plasma(serum) carbon dioxide in different condition by using capping or not capping and controling time in four kinds of tubes after col ecting blood samples simultaneously Results: There were no significant differences in the same time period among the results of determining carbon dioxide in three kinds of tubes with capping after water bath heating in 37℃ with 3 hours, while there’s highly significant differences in taditonal drying tube with out capping in determing as the results of carbon dioxide determining in each kinds of tubes with out capping were lower than that with capping in each period. Moreover, the results were droped gradual y with storage period prolonging.Conclusion:The plasma( serum) dioxide obtained by separating gel tubes and Heparin lithium tube were not only preferably in preventing from dioxide losing but also had less impact on carbon dioxide determining with its chemical composition. In addtion they could provide fast seperation of blood specimens for clinic laboratory. Consequently, separation gel tube and Heparin lithium tube are more appropriate for determining carbon dioxide than traditional drying tube.